EATON - MOELLER Z-S48/SS Z-S48/SS 265536 Y7-265536 EATON ELECTRIC Impulse relay, 48AC/24DC, 2NO, 16A, 50Hz, 1SU View larger
Images are for illustrative purposes only. Please refer to data sheet for details

Z-S48/SS 265536 Y7-265536 EATON ELECTRIC Impulse relay, 48AC/24DC, 2NO, 16A, 50Hz, 1SU

Z-S48/SS

265536

Y7-265536

EATON - MOELLER

1 Pcs.

Impulse relay, 48AC/24DC, 2NO, 16A, 50Hz, 1SU Z-S48/SS Eaton Distribution parts. Impulse relay, 48AC/24DC, 2NO, 16A, 50Hz, 1SU Impulse relay, control voltage 48V AC / 24V DC, function: 2 N/O, rated operational current at 250V AC according to IEC/EN 60669-2-2: 16A, standard front dimension 45 mm, mounting width 1 SU (17.5mm), top-hat rail mounting, terminal cross-section 0.5–10 mm² solid and flexible / 0.5–6 mm² flexible with ferrule

Automation > Latching relay
Modular Switchgear – Others and Accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Distribution parts
Catalog Number
265536
Model Code
Z-S48/SS
EAN
4015082655365
Product Length/Depth
80 mm
Product Height
70 mm
Product Width
17.5 mm
Product Weight
0.136 kg
Compliances
RoHS conform

Product specifications

Mounting method
DIN rail
Control voltage 1 type
AC
Ambient operating temperature - max
45 °C
Ambient operating temperature - min
-20 °C
Control voltage 1 - max
48 V
Control voltage 1 - min
48 V
Control voltage 2 - max
24 V
Control voltage 2 - min
24 V
Frequency control voltage 1 - max
50 Hz
Frequency control voltage 1 - min
50 Hz
Frequency control voltage 2 - max
50 Hz
Frequency control voltage 2 - min
50 Hz
Heat dissipation per pole, current-dependent
1.5 W
Incandescent lamp load - max
0 W
Load fluorescent lamp - max
0 VA
Load fluorescent lamp (duo circuit) - max
0 VA
Load fluorescent lamp (parallel compensated) - max
0 VA
Number of contacts (change-over contacts)
0
Number of contacts (normally closed contacts)
0
Number of contacts (normally open contacts)
2
Rated operational current for specified heat dissipation (In)
16 A
Rated switch current
16 A
Equipment heat dissipation, current-dependent
3 W
Supply voltage - max
250 V
Supply voltage - min
250 V
Switching current (cos phi = 0.6) - max
0 A
Width in number of modular spacings
1
Built-in depth
60 mm
Operating mode
Manual operation possible
Control voltage 2 type
DC
Voltage type
AC
Functions
Other

ETIM for 265536 Modular devices for distribution board/surface mounting (EC000188)
Feature Name Feature Value
Function (EF000030) Other
Mounting method (EF000003) DIN rail
Width in number of modular spacings (EF002950) 1
Built-in depth (EF000218) 60 mm
Number of contacts as normally open contact (EF008256) 2
Number of contacts as normally closed contact (EF008255) 0
Number of contacts as change-over contact (EF008257) 0
Control voltage 1 (EF002952) 48 V
Type of control voltage 1 (EF002954) AC
Frequency control voltage 1 (EF002956) 50 Hz
Control voltage 2 (EF002953) 24 V
Type of control voltage 2 (EF002955) DC
Frequency control voltage 2 (EF002957) 50 Hz
Rated switch current (EF006706) 16 A
Supply voltage (EF004127) 250 V
Voltage type (supply voltage) (EF002991) AC
Max. incandescent lamp load (EF004952) 0 W
Max. load fluorescent lamp (EF004971) 0 VA
Max. load fluorescent lamp (Duo circuit) (EF004972) 0 VA
Max. load fluorescent lamp (parallel compensated) (EF004973) 0 VA
Max. switching current (cos phi = 0.6) (EF004920) 0 A
Suitable for manual operation (EF002978) Yes

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.