PV DC SPD box 2IN+2OUT Type 2 Photovoltaic DC string box, 2x IN + 2x OUT, SPD Type2, MC4 connection, IKA-1/8, outdoor protected Photovoltaic DC string box, factory assembled by Eaton: IEC 61439-2 Annex-DD. For inverters with 2 MPP tracker: 2x IN + 2x OUT, Integrated devices: PV-surge-protection-device type 2, MC4 connectors at the bottom of the box, IKA box 1-row with 8 module units and transparent window, Outdoor installation without solar radiation. For safe operation please note the min. and max. permissible ambient air temperature in the technical data sheet

Automation > Photovoltaic DC Stringbox
Compact Distribution Boxes

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton xComfort IKA SOLAR photovoltaic DC stringbox
Catalog Number
EP-501989
Model Code
IKA-SOL20-X22-T2-1/8-MC4-B
EAN
9010653063919
Product Length/Depth
118 mm
Product Height
268 mm
Product Width
238 mm
Product Weight
5.19 kg
Certifications
IEC 61439-2 Annex DD

Delivery program

Color
Gray

Technical data - electrical

Voltage protection level
3.8 KV
Input voltage DC - max
1000 V
Rated operational voltage (Ue)
1000 V
Rated current InA of the switchgear assembly
2 x 19.5 A
Rated current Inc of a circuit
19.5 A
Input current per string - max
19.5 A
Output current - max
19.5 A
Discharge current In (8/20 µs)
20 kA
Discharge current Itotal (8/20 µs) - max.
40 kA

Technical data - mechanical

Type of inlet
Other
Enclosure material
Polycarbonate (plastic)
Height of enclosure
231 mm
Length/depth of enclosure
115 mm
Width of enclosure
238 mm
Mounting method
Surface mounting
Conductor cross section
PE: 16 - 25 mm²
min./max.: 6 mm²
Material
Plastic
Degree of Protection
IP65
Impact strength
IK10
Protection class
II (totally insulated)
Operating temperature - min
-25 °C
Operating temperature - max
40 °C
Relative humidity (Indoor installation) - max
70% (+30°C)
57% (+40°C)
95% (-5°C - +30°C)
Relative humidity (Outdoor installation) - max
60% (+35°C)
46% (+40°C)
100% (-25°C - +27°C)
Number of conduit inlets
2
Number of inputs
2
Number of module space units per row
8
Number of rows
1
Number of string inputs
2
Fuse type
Other
For fuse size
Other
Fuse size input
0 A
Cover/door color
Transparent
Connection type
MC4
DC Generator switch
None
DC String circuit-breaker
0 A
DC Surge arrester
Type 2
PV string on inverter input
2 x IN + 2 x OUT
String protection
None
Switchgear assembly
PVA

Design verification as per IEC/EN 61439 - technical data

Ambient air temperature - min.
-25 °C
Ambient air temperature - max.
40 °C
Ambient air temperature (daily average) - max.
35 °C

Additional information

Communication bus
Other
Communications protocol
Other
Delivery condition
Ready to connect
Fitted with:
Grounding connection
Location type
Outdoor installation – without solar radiation
Monitoring function
No
Rated diversity factor (RDF)
1

ETIM for EP-501989 Renewable energy systems (EC003857)
Feature Name Feature Value
Number of inputs (EF000318) 2
Max. input voltage DC (EF015870) 1000 V
Width (EF000008) 238 mm
Height (EF000040) 268 mm
Depth (EF000049) 118 mm
String protection (EF013598) None
Material (EF002169) Plastic
Degree of protection (IP) (EF005474) IP65
Impact strength (EF004293) IK10
Fuse type (EF011923) Other
For fuse size (EF008316) Other
Fuse size input (EF013599) 0 A
Category type 1 (EF004229) No
Category type 2 (EF004230) No
Category type 3 (EF004231) No
Communications protocol (EF005669) Other
Communication bus (EF005668) Other
Monitoring function (EF013608) No
Operating temperature (EF001742) -25 °C
Max. input current per string (EF017440) 19.5 A
Max. output current (EF001315) 19.5 A
Colour (EF000007) Grey
Number of conduit inlets (EF000437) 2
Type of inlet (EF001455) Other
Number of string inputs (EF017441) 2
With earthing connection (EF006304) Yes
Equipped with switch disconnector (EF007957) No