EATON - MOELLER EC4E-221-6D4R1 EC4E-221-6D4R1 114296 4560853 EATON ELECTRIC I/O expansion, integrated, 24 V DC, 6DI, 4DO(R) View larger
Images are for illustrative purposes only. Please refer to data sheet for details

EC4E-221-6D4R1 114296 4560853 EATON ELECTRIC I/O expansion, integrated, 24 V DC, 6DI, 4DO(R)

EC4E-221-6D4R1

114296

4560853

EATON - MOELLER

1 Pcs.

I/O expansion, integrated, 24 V DC, 6DI, 4DO(R) EC4E-221-6D4R1 I/O expansion via CANopen. Can be used for XC100/200, EC4P, XV-…

Automation > PLC digital I/O-module
EC4P PLCs

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

EL-Nummer (Norway)
4560853
I/O expansion, integrated, 24 V DC, 6DI, 4DO(R)
I/O expansion via CANopen. Can be used for XC100/200, EC4P, XV-…

Delivery program

Product range
Remote I/O systems
Compact PLCs
Subrange
I/O expansions digital/analog
Basic function
Expansions
Description
usable via CANopen®
Function
CANopen® expansion EC4E
Inputs
Inputs expansion (number)
Digital: 6
Additional features
Real time clock
Supply voltage
24 V DC
For use with
XC100
XC200
EC4P
For use with
XC100/200, EC4P, MFD4 (via CANopen®)

Technical data

General
Dimensions (W x H x D)
71.5 x 90 x 58 (4 PE) mm
Weight
0.2 kg
Mounting
Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Terminal capacities
Solid
0.2/4 (AWG 22 - 12) mm2
Flexible with ferrule
0.2/2.5 (AWG 22 - 12) mm2
Standard screwdriver
0.8 x 3.5 mm
Max. tightening torque
0.6 Nm
Climatic environmental conditions
Operating ambient temperature
-25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2 °C
Condensation
Take appropriate measures to prevent condensation
Storage [ϑ]
-40 - +70 °C
Ambient conditions, mechanical
Mounting position
Vertical or horizontal
Electromagnetic compatibility (EMC)
Overvoltage category/pollution degree
II/2
Electrostatic discharge (ESD)applied standard
IEC/EN 61000-4-2, Level 3
Electrostatic discharge (ESD)Air discharge
8 kV
Electromagnetic fields (RFI) to IEC EN 61000-4-3
10 V/m
Burst
according to IEC/EN 61000-4-4 kV
power pulses (Surge)
2 kV (supply cables, symmetrical, EASY...AC)
0.5 kV (supply cables, symmetrical, easy-DC)
according to IEC/EN 61000-4-5
Immunity to line-conducted interference to (IEC/EN 61000-4-6)
10 V
Insulation resistance
Clearance in air and creepage distances
EN 50178, UL 508, CSA C22.2, No. 142
Insulation resistance
EN 50178
Power supply
Rated operational voltage [Ue]
24 DC (-15/+20%) V
Permissible range [Ue]
20.4 - 28.8 V DC
Residual ripple
≦ 5 %
Input current
150 mA at Ueat no load
Voltage dips
≤ 20
(IEC/EN 61131-2) ms
Heat dissipation [P]
Normally 3.5 W
Interfaces
CANopen®Data transfer rate
500 kBit/s, 25 m250 kBit/s, 40m125 kBit/s, 125 m50 kBit/s, 300 m20 kBit/s, 700 m10 kBit/s, 1000 m
CANopen®Bus termination (first and last station)
Via integrated Dip switch
CANopen®Connection types
2 x terminals (see terminal capacity)
Mode slaveStations
max. 62 Number
Mode slavePDO type
Asynchronous, cyclic, acyclic
Mode slaveControl contact rated current
to DS301V4
Digital inputs 24 V DC
Number
6
Potential isolation
from the outputs: yes
Rated operational voltage [Ue]
24 V DC
Input voltage
< 5 (R1 - R6) at signal "0"
> 15 (R1 - R6) at signal "1" V DC
Input current on 1 signalInput current at signal 1
3.3 (R1 to R6 (R12)) mA
Deceleration time
20 (from “0” to “1”, debounce ON)
Normally 0.25 (R1 - R12) (from “0” to “1”, debounce OFF)
20 (from „1“ to „0“) ms
Cable length
100 (unshielded) m
Relay outputs
Outputs in groups of
1
Parallel switching of outputs for increased output
Not permissible
Protection of an output relay
Miniature circuit-breaker B16 or fuse 8 A (slow)
Potential isolation
from power supply: yes
From the inputs: yes
to PC interface, memory card, network NET, easyLink
Safe isolation according to EN 50178: 300 V AC
Basic isolation: 600 V AC
Lifespan, mechanical [Operations]
10 x 106
ContactsConventional thermal current (10 A UL)
6 A
ContactsRecommended for load: 12 V AC/DC
> 500 mA
ContactsShort-circuit-proof cos ϕ = 1, characteristic B16 at 600 A
16 A
ContactsShort-circuit-proof cos ϕ = 0.5 to 0.7, characteristic B16 at 900 A
16 A
ContactsRated impulse withstand voltage Uimpof contact coil
6 kV
ContactsRated operational voltage [Ue]
250 V AC
Rated insulation voltage [Ui]
250 V AC
Safe isolation according to EN 50178
300 between coil and contact
300 between two contacts V AC
Breaking capacityAC-15, 250 V AC, 3 A (600 Ops./h) [Operations]
300000
Breaking capacityDC-13, L/R ≦ 150 ms, 24 V DC, 1 A (500 S/h) [Operations]
200000
Filament bulb load1000 W at 230/240 V AC [Operations]
25000
Filament bulb load500 W at 115/120 V AC [Operations]
25000
Fluorescent lamp loadFluorescent lamp load 10 x 58 W at 230/240 V ACWith upstream electrical device [Operations]
25000
Fluorescent lamp loadFluorescent lamp load 10 x 58 W at 230/240 V ACUncompensated [Operations]
25000
Fluorescent lamp loadFluorescent lamp load 1 x 58 W at 230/240 V AC, conventional, compensated [Operations]
25000
Switching frequencyMechanical operations
10 x 106
Switching frequencySwitching frequency
10 Hz
Switching frequencyResistive load/lamp load
2 Hz
Switching frequencyInductive load
0.5 Hz
UL/CSAUninterrupted current at 240 V AC
10 A
UL/CSAUninterrupted current at 24 V DC
8 A
UL/CSAACControl Circuit Rating Codes (utilization category)
B 300 Light Pilot Duty
UL/CSAACMax. rated operational voltage
300 V AC
UL/CSAACmax. thermal continuous current cos ϕ = 1 at B 300
5 A
UL/CSAACmax. make/break cos ϕ ≠ capacity 1 at B 300
3600/360 VA
UL/CSADCControl Circuit Rating Codes (utilization category)
R 300 Light Pilot Duty
UL/CSADCMax. rated operational voltage
300 V DC
UL/CSADCMax. thermal uninterrupted current at R 300
1 A
UL/CSADCMax. make/break capacity at R 300
28/28 VA
Network easyNet
Bus termination (first and last station)
Via integrated Dip switch

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
0 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
3.4 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+55 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

PLC's (EG000024) / PLC digital I/O-module (EC001419)
Electric engineering, automation, process control engineering / Control / Programmable logic control (SPS) / SPS digital input/output module ([email protected] [AKE527014])
Supply voltage AC 50 Hz
0 - 0 V
Supply voltage AC 60 Hz
0 - 0 V
Supply voltage DC
20.4 - 28.8 V
Voltage type of supply voltage
DC
Number of digital inputs
6
Number of digital outputs
4
Digital inputs configurable
No
Digital outputs configurable
No
Input current at signal 1
3.3 mA
Permitted voltage at input
0 - 0 V
Type of voltage (input voltage)
DC
Type of digital output
Relay
Output current
8 A
Permitted voltage at output
0 - 0 V
Type of output voltage
AC/DC
Short-circuit protection, outputs available
No
Redundancy
No
Type of electric connection
Screw connection
Time delay at signal exchange
20 - 20 ms
Suitable for safety functions
No
Category according to EN 954-1
SIL according to IEC 61508
None
Performance level acc. EN ISO 13849-1
None
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
None
Explosion safety category for dust
None
Width
71.5 mm
Height
90 mm
Depth
58 mm

Approvals

North America Certification
Request filed for UL and CSA
Specially designed for North America
No
Current Limiting Circuit-Breaker
No
Degree of Protection
IEC: IP20, UL/CSA Type: -

Dimensions

252X008

ETIM for 114296 PLC's (EC001419)
Feature Name Feature Value
Supply voltage AC 50 Hz (EF007532) 0 V
Supply voltage AC 60 Hz (EF007533) 0 V
Supply voltage DC (EF007534) 20.4 V
Voltage type (supply voltage) (EF002991) AC/DC
Number of digital inputs (EF001992) 6
Number of digital outputs (EF001993) 4
Digital inputs configurable (EF008516) No
Digital outputs configurable (EF008520) No
Input current at signal 1 (EF001428) 3.3 mA
Permitted voltage at input (EF007554) 0 V
Type of voltage (input voltage) (EF003033) AC/DC
Type of digital output (EF003601) Relay
Output current (EF003202) 8 A
Permitted voltage at output (EF007553) 0 V
Type of output voltage (EF008222) AC/DC
Short-circuit protection, outputs available (EF003203) No
Redundancy (EF003156) No
Type of electric connection (EF003961) Screw connection
Time delay at signal change (EF002382) 20 ms
Suitable for safety functions (EF001597) No
SIL according to IEC 61508 (EF009889) None
Performance level according to EN ISO 13849-1 (EF007399) None
Appendant operation agent (Ex ia) (EF004141) No
Appendant operation agent (Ex ib) (EF004142) No
Explosion safety category for gas (EF003997) None
Explosion safety category for dust (EF003998) None
Width (EF000008) 71.5 mm
Height (EF000040) 90 mm
Depth (EF000049) 58 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.