EATON - MOELLER EASY410-DC-TE EASY410-DC-TE 114294 0004560803 EATON ELECTRIC I/O expansion, 24 V DC, 6DI, 4DO-Trans, easyLink View larger
Images are for illustrative purposes only. Please refer to data sheet for details

EASY410-DC-TE 114294 0004560803 EATON ELECTRIC I/O expansion, 24 V DC, 6DI, 4DO-Trans, easyLink

EASY410-DC-TE

114294

0004560803

EATON - MOELLER

1 Pcs.

I/O expansion, 24 V DC, 6DI, 4DO-Trans, easyLink Easy Extension Module; 24 V DC; 6 ED, 4 SD Control relay expansion, rated operating voltage 24VDC, 6 digital inputs 24VDC, 4 transistor outputs, can be used via easyLink for easy700, easy800, MFD-CP8/CP10, EC4P, EC4E, ES4P

Automation > Logic module
EASY programmable relays and MFD displays

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

I/O expansion, 24 V DC, 6DI, 4DO-Trans, easyLink
Control relay expansion, rated operating voltage 24VDC, 6 digital inputs 24VDC, 4 transistor outputs, can be used via easyLink for easy700, easy800, MFD-CP8/CP10, EC4P, EC4E, ES4P

Delivery program

Product range
Control relay easyRelay
Multi-function-display MFD-Titan
Product range
Remote I/O systems
Compact PLCs
Subrange
I/O expansions digital
Basic function
Expansions
Description
Can be used through easyLink
Function
Expansions EASY…
Accessories
I/O expansions, digital
Inputs
Inputs expansion (number)
digital: 6
Outputs
Transistor
4
Supply voltage
24 V DC
For use with
easy700
easy800
EC4P
MFD-CP8…
MFD-CP10...

Technical data

General
Dimensions (W x H x D)
71.5 x 90 x 58 (4 PE) mm
Weight
0.2 kg
Climatic environmental conditions
Operating ambient temperature
-25 to + 55
cold as per IEC 60068-2-1
heat as per IEC 60068-2-2 °C
Condensation
Take appropriate measures to prevent condensation
Storage [ϑ]
-40 - +70 °C
relative humidity
5 - 95 %
Air pressure (operation)
795 - 1080 hPa
Ambient conditions, mechanical
Protection type (IEC/EN 60529, EN50178, VBG 4)
IP20
Vibrations (IEC/EN 60068-2-6)Constant amplitude 0.15 mm
10 - 57 Hz
Vibrations (IEC/EN 60068-2-6)Constant acceleration 2 g
57 - 150 Hz
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms
18 Impacts
Drop to IEC/EN 60068-2-31 [Drop height]
50 mm
Free fall, packaged (IEC/EN 60068-2-32)
1 m
Mounting position
Vertical or horizontal
Electromagnetic compatibility (EMC)
Overvoltage category/pollution degree
II/2
Electrostatic discharge (ESD)applied standard
IEC EN 61000-4-2, Level 3
Electrostatic discharge (ESD)Air discharge
8 kV
Electrostatic discharge (ESD)Contact discharge
6 kV
Burst
according to IEC/EN 61000-4-4
Supply cables: 2
Signal cables: 2 kV
power pulses (Surge)
2 kV (supply cables, symmetrical, EASY...AC)
0.5 kV (supply cables, symmetrical, easy-DC)
according to IEC/EN 61000-4-5
Immunity to line-conducted interference to (IEC/EN 61000-4-6)
10 V
Insulation resistance
Insulation resistance
EN 50178
Power supply
Rated operational voltage [Ue]
24 DC (-15/+20%) V
Rated operational voltage [Ue]
24 DC (-15/+20%) V
Permissible range [Ue]
20.4 - 28.8 V DC
Residual ripple
≦ 5 %
Input current
140 mA at Ue
Voltage dips
≤ 10
(IEC/EN 61131-2) ms
Heat dissipation [P]
3.5 W
Digital inputs 24 V DC
Number
6
Status Display
LCD-Display
Potential isolation
from the outputs: yes
Rated operational voltage [Ue]
24 V DC
Input voltage
< 5 (R1 - R6) at signal "0"
> 15 (R1 - R6) at signal "1" V DC
Input current on 1 signalInput current at signal 1
3.3 (R1 to R6 (R12)) mA
Deceleration time
20 (from “0” to “1”, debounce ON)
Normally 0.25 (R1 - R6) (from “0” to “1”, debounce OFF)
20 (from “1” to “0”, debounce ON) ms
Cable length
100 (unshielded) m
Transistor outputs
Number
4
Rated operational voltage [Ue]
24 V DC
Permissible range [Ue]
20.4 - 28.8 V DC
Residual ripple
5 %
Supply current
Norm./max. 9/16 at signal 0
12/22 at signal 1 mA
Protection against polarity reversal
yes (Caution: A short circuit will result if 0 V or earth is applied to the outputs in the event that the supply voltage is connected to the wrong poles.)
Potential isolation
to the memory card: yes
Rated operational current at signal „1” DC per channel [Ie]
max. 0.5 A
Lamp load without Rvper channel
5 W
Residual current on 0 signal per channel
< 0.1 mA
Max. output voltage
2.5 (signal 0 at external load < 10 MΩ)
U = Ue- 1 V (signal 1 at Ie= 0.5 A) V
Short-circuit protection
Yes, thermal (evaluation through diagnostics input R16)
Short-circuit tripping current for Ra≦ 10 mΩ
0.7 ≦ Ie≦ 2 per output A
Total short-circuit current
8 A
Peak short-circuit current
16 A
Thermal cutout
Yes
Max. operating frequency with constant resistive load
40000 Operations/h
Parallel connection of outputsWith resistive load, inductive load with external suppressor circuit, combination within a group
Group 1: Q1 to Q4
Parallel connection of outputsNumber of outputs [max.]
4
Parallel connection of outputsMax. total current
2 (Caution! Outputs must be actuated simultaneously and for the same length of time.) A
Output status indication
LCD display (if provided)
Supply voltage UAux
Protection against polarity reversal
yes (Caution: A short circuit will result if 0 V or earth is applied to the outputs in the event that the supply voltage is connected to the wrong poles.)

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
0 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
3.5 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+55 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

PLC's (EG000024) / Logic module (EC001417)
Electric engineering, automation, process control engineering / Control / Programmable logic control (SPS) / Logic module ([email protected] [AKE539014])
Supply voltage AC 50 Hz
0 - 0 V
Supply voltage AC 60 Hz
0 - 0 V
Supply voltage DC
20.4 - 28.8 V
Voltage type of supply voltage
DC
Switching current
0.5 A
Number of analogue inputs
0
Number of analogue outputs
0
Number of digital inputs
6
Number of digital outputs
4
With relay output
No
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces Wireless
0
Number of HW-interfaces other
1
With optical interface
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for MODBUS
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Radio standard Bluetooth
No
Radio standard WLAN 802.11
No
Radio standard GPRS
No
Radio standard GSM
No
Radio standard UMTS
No
IO link master
No
Redundancy
No
With display
No
Degree of protection (IP)
IP20
Basic device
No
Expandable
No
Expansion device
Yes
With timer
No
Rail mounting possible
Yes
Wall mounting/direct mounting
Yes
Front build in possible
No
Rack-assembly possible
No
Suitable for safety functions
No
Category according to EN 954-1
None
SIL according to IEC 61508
None
Performance level acc. EN ISO 13849-1
None
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
None
Explosion safety category for dust
None
Width
71.5 mm
Height
90 mm
Depth
58 mm

Approvals

North America Certification
Request filed for UL and CSA
Degree of Protection
IEC: IP20, UL/CSA Type: -

Dimensions

252X008

ETIM for 114294 PLC's (EC001417)
Feature Name Feature Value
Supply voltage AC 50 Hz (EF007532) 0 V
Supply voltage AC 60 Hz (EF007533) 0 V
Supply voltage DC (EF007534) 20.4 V
Voltage type (supply voltage) (EF002991) DC
Switching current (EF000188) 0.5 A
Power consumption (EF000346) None W
Number of analogue inputs (EF001994) 0
Number of analogue outputs (EF001995) 0
Number of digital inputs (EF001992) 6
Number of digital outputs (EF001993) 4
With relay output (EF003198) false
Number of HW-interfaces industrial Ethernet (EF003020) 0
Number of interfaces PROFINET (EF006932) 0
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 0
Number of HW-interfaces serial TTY (EF003024) 0
Number of HW-interfaces USB (EF003025) 0
Number of HW-interfaces parallel (EF003026) 0
Number of HW-interfaces wireless (EF006933) 0
Number of HW-interfaces other (EF003027) 1
With optical interface (EF003028) false
Supporting protocol for EtherCAT (EF017564) false
Supporting protocol for TCP/IP (EF003050) false
Supporting protocol for PROFIBUS (EF003052) false
Supporting protocol for CAN (EF003053) false
Supporting protocol for INTERBUS (EF003054) false
Supporting protocol for ASI (EF003051) false
Supporting protocol for KNX (EF003055) false
Supporting protocol for Modbus (EF003057) false
Supporting protocol for Data-Highway (EF003058) false
Supporting protocol for DeviceNet (EF003059) false
Supporting protocol for SUCONET (EF003060) false
Supporting protocol for LON (EF003017) false
Supporting protocol for PROFINET IO (EF007525) false
Supporting protocol for PROFINET CBA (EF007524) false
Supporting protocol for SERCOS (EF006657) false
Supporting protocol for Foundation Fieldbus (EF007522) false
Supporting protocol for EtherNet/IP (EF007521) false
Supporting protocol for AS-Interface Safety at Work (EF007519) false
Supporting protocol for DeviceNet Safety (EF007520) false
Supporting protocol for INTERBUS-Safety (EF006662) false
Supporting protocol for PROFIsafe (EF007526) false
Supporting protocol for SafetyBUS p (EF007527) false
Supporting protocol for other bus systems (EF003062) false
Radio standard Bluetooth (EF007178) false
Radio standard WLAN 802.11 (EF007179) false
Radio standard GPRS (EF008523) false
Radio standard GSM (EF008524) false
Radio standard UMTS (EF008525) false
IO link master (EF007298) false
Redundancy (EF003156) false
With display (EF000458) false
Degree of protection (IP) (EF005474) IP20
Basic device (EF007279) false
Expandable (EF000119) false
Expansion device (EF007163) true
With time switch clock (EF000256) false
Suitable for rail mounting (EF003972) true
Wall mounting/direct mounting (EF007020) true
Front built-in possible (EF007016) false
Rack-assembly possible (EF007018) false
Suitable for safety functions (EF001597) false
SIL according to IEC 61508 (EF009889) None
Performance level according to EN ISO 13849-1 (EF007399) None
Appendant operation agent (Ex ia) (EF004141) false
Appendant operation agent (Ex ib) (EF004142) false
Explosion safety category for gas (EF003997) None
Explosion safety category for dust (EF003998) None
Certified for UL hazardous location class I (EF017622) false
Certified for UL hazardous location class II (EF017625) false
Certified for UL hazardous location class III (EF017627) false
Certified for UL hazardous location division 1 (EF017628) false
Certified for UL hazardous location division 2 (EF017629) false
Certified for UL hazardous location group A (acetylene) (EF017632) false
Certified for UL hazardous location group B (hydrogen) (EF017633) false
Certified for UL hazardous location group C (ethylene) (EF017635) false
Certified for UL hazardous location group D (propane) (EF017636) false
Certified for UL hazardous location group E (metal dusts) (EF017637) false
Certified for UL hazardous location group F (carbonaceous dusts) (EF017638) false
Certified for UL hazardous location group G (non-conductive dusts) (EF017639) false
Width (EF000008) 72 mm
Height (EF000040) 90 mm
Depth (EF000049) 57 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.