EATON - MOELLER HNB-C10/1N/003 HNB-C10/1N/003 195125 EATON ELECTRIC RCD/MCB combination, 10 A, 30 mA, MCB trip characteristic: C, 1p+N, RCD.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

HNB-C10/1N/003 195125 EATON ELECTRIC RCD/MCB combination, 10 A, 30 mA, MCB trip characteristic: C, 1p+N, RCD..

HNB-C10/1N/003

195125

Y7-195125

EATON - MOELLER

1 Pcs.

RCD/MCB combination, 10 A, 30 mA, MCB trip characteristic: C, 1p+N, RCD trip characteristic: AC RCD/MCB combination switch, HNB, 1-pole+N, rated current In: 10 A, rated fault current: 0.03 A, rated breaking capacity according to IEC/EN 61009: 6 kA, Switchgear for residential and commercial applications

Automation > Earth leakage circuit breaker
Modular Switchgear - Differential

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

RCD/MCB combination, 10 A, 30 mA, MCB trip characteristic: C, 1p+N, RCD trip characteristic: AC
RCD/MCB combination switch, HNB, 1-pole+N, rated current In: 10 A, rated fault current: 0.03 A, rated breaking capacity according to IEC/EN 61009: 6 kA, Switchgear for residential and commercial applications

General specifications
Product name
Eaton Moeller series xPole - HNB RCBO - residual-current circuit breaker with overcurrent protection
Part no.
HNB-C10/1N/003
EAN
9010238060784
Product Length/Depth
80 millimetre
Product height
73 millimetre
Product width
35 millimetre
Product weight
0.203 kilogram
Compliances
CE Marked
RoHS conform
Certifications
CE
Product Tradename
xPole - HNB
Product Type
RCBO - Residual-current circuit breaker with overcurrent protection
Product Sub Type
None
Globally Marketable
Yes
Delivery program
Number of poles (protected)
1
Number of poles (total)
2
Release characteristic
C
Amperage Rating
10 A
Rated current
10 A
Fault current rating
0.03 A
Type
RCBO
Technical Data - Electrical
Voltage type
AC
Voltage rating
230 V
Rated operational voltage (Ue) - max
230 V
Rated insulation voltage (Ui)
500 V
Rated impulse withstand voltage (Uimp)
4 kV
Frequency rating
50 Hz
Leakage current type
AC
Rated short-circuit breaking capacity (EN 60947-2)
0 kA
Rated short-circuit breaking capacity (EN 61009)
6 kA
Rated short-circuit breaking capacity (EN 61009-1)
6 kA
Rated short-circuit breaking capacity (IEC 60947-2)
0 kA
Surge current capacity
0.25 kA
Disconnection characteristic
Undelayed
Pollution degree
2
Technical Data - Mechanical
Width in number of modular spacings
2
Built-in depth
69.5 mm
Degree of protection
IP20
Connectable conductor cross section (solid-core) - min
1 mm²
Connectable conductor cross section (solid-core) - max
25 mm²
Connectable conductor cross section (multi-wired) - min
1 mm²
Connectable conductor cross section (multi-wired) - max
25 mm²
Design verification as per IEC/EN 61439 - technical data
Ambient operating temperature - max
40 °C
Ambient operating temperature - min
-25 °C
Additional information
Current limiting class
3
Features
Concurrently switching N-neutral

Technical data ETIM 8.0

Circuit breakers and fuses (EG000020) / Earth leakage circuit breaker (EC000905)
Electric engineering, automation, process control engineering / Electrical installation, device / Residual current protection system / MCB/RCCB combination ([email protected] [AFZ810015])
Number of poles (total)
2
Number of protected poles
1
Rated voltage
230 V
Rated insulation voltage Ui
500 V
Rated impulse withstand voltage Uimp
4 kV
Rated current
10 A
Rated fault current
0.03 A
Leakage current type
AC
Current limiting class
3
Rated short-circuit breaking capacity according to EN 61009
6 kA
Rated short-circuit breaking capacity according to IEC 60947-2
0 kA
Rated short-circuit breaking capacity Icn according to EN 61009-1
6 kA
Disconnection characteristic
Undelayed
Surge current capacity
0.25 kA
Voltage type
AC
Frequency
50 Hz
Release characteristic
C
Concurrently switching neutral conductor
Yes
With interlocking device
No
Over voltage category
3
Pollution degree
2
Ambient temperature during operating
-25 - 40 °C
Width in number of modular spacings
2
Built-in depth
69.5 mm
Flush-mounted installation
No
Anti-nuisance tripping version
No
Degree of protection (IP)
IP20
Connectable conductor cross section solid-core
1 - 25 mm²
Connectable conductor cross section multi-wired
1 - 25 mm²

ETIM for 195125 Circuit breakers and fuses (EC000905)
Feature Name Feature Value
Number of poles (total) (EF008618) 2
Number of protected poles (EF005548) 1
Rated voltage (EF000228) 230 V
Rated insulation voltage Ui (EF001366) 500 V
Rated impulse withstand voltage Uimp (EF011980) 4 kV
Rated current (EF000227) 10 A
Rated fault current (EF002358) 0.03 A
Leakage current type (EF002560) AC
Current limiting class (EF002568) 3
Rated short-circuit breaking capacity according to EN 61009 (EF012628) 6 kA
Rated short-circuit breaking capacity according to IEC 60947-2 (EF006065) 0 kA
Rated short-circuit breaking capacity Icn according to EN 61009-1 (EF011981) 6 kA
Disconnection characteristic (EF012587) Undelayed
Surge current capacity (EF002564) 0.25 kA
Voltage type (EF000187) AC
Frequency (EF005455) 50 Hz
Release characteristic (EF000889) C
Concurrently switching neutral conductor (EF005997) Yes
With interlocking device (EF007385) No
Over voltage category (EF002569) 3
Pollution degree (EF002570) 2
Ambient temperature during operating (EF007515) -25 °C
Width in number of modular spacings (EF002950) 2
Built-in depth (EF000218) 69.5 mm
Anti-nuisance tripping version (EF009497) No
Degree of protection (IP) (EF005474) IP20
Connectable conductor cross section solid-core (EF007337) 1 mm²
Connectable conductor cross section multi-wired (EF007343) 1 mm²

Product Datasheet