EATON - MOELLER HNB-B13/1N/003-A HNB-B13/1N/003-A 195132 EATON ELECTRIC RCD/MCB combination, 13 A, 30 mA, MCB trip characteristic: B, 1p+N, R.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

HNB-B13/1N/003-A 195132 EATON ELECTRIC RCD/MCB combination, 13 A, 30 mA, MCB trip characteristic: B, 1p+N, R..

HNB-B13/1N/003-A

195132

EATON - MOELLER

1 Pcs.

RCD/MCB combination, 13 A, 30 mA, MCB trip characteristic: B, 1p+N, RCD trip characteristic: A RCD/MCB combination switch, HNB, 1-pole+N, rated current In: 13 A, rated fault current: 0.03 A, rated breaking capacity according to IEC/EN 61009: 6 kA, Switchgear for residential and commercial applications

Automation > Earth leakage circuit breaker
Modular Switchgear - Differential

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

An RCD/MCB combination switch provides dual-action protection against overcurrent conditions and residual earth leakage currents in electrical installations. This device is commonly applied in distribution boards to protect sensitive loads and maintain safety compliance. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Number of poles (total) (EF008618): 2
  • Number of protected poles (EF005548): 1
  • Rated voltage (EF000228): 230 V
  • Rated insulation voltage Ui (EF001366): 500 V
  • Rated impulse withstand voltage Uimp (EF011980): 4 kV
  • Rated current (EF000227): 13 A
  • Rated fault current (EF002358): 0.03 A
  • Leakage current type (EF002560): A
  • Current limiting class (EF002568): 3
  • Disconnection characteristic (EF012587): Undelayed
  • Surge current capacity (EF002564): 0.25 kA
  • Voltage type (EF000187): AC
  • Frequency (EF005455): 50 Hz
  • Release characteristic (EF000889): B
  • Concurrently switching neutral conductor (EF005997): Yes
  • With interlocking device (EF007385): No

More info

▲
RCD/MCB combination, 13 A, 30 mA, MCB trip characteristic: B, 1p+N, RCD trip characteristic: A
RCD/MCB combination switch, HNB, 1-pole+N, rated current In: 13 A, rated fault current: 0.03 A, rated breaking capacity according to IEC/EN 61009: 6 kA, Switchgear for residential and commercial applications

General specifications
Product name
Eaton Moeller series xPole - HNB RCBO - residual-current circuit breaker with overcurrent protection
Part no.
HNB-B13/1N/003-A
EAN
9010238060951
Product Length/Depth
80 millimetre
Product height
73 millimetre
Product width
35 millimetre
Product weight
0.203 kilogram
Compliances
CE Marked
RoHS conform
Certifications
CE
Product Tradename
xPole - HNB
Product Type
RCBO - Residual-current circuit breaker with overcurrent protection
Product Sub Type
None
Globally Marketable
Yes
Delivery program
Number of poles (protected)
1
Number of poles (total)
2
Release characteristic
B
Amperage Rating
13 A
Rated current
13 A
Fault current rating
0.03 A
Type
RCBO
Technical Data - Electrical
Voltage type
AC
Voltage rating
230 V
Rated operational voltage (Ue) - max
230 V
Rated insulation voltage (Ui)
500 V
Rated impulse withstand voltage (Uimp)
4 kV
Frequency rating
50 Hz
Leakage current type
A
Rated short-circuit breaking capacity (EN 60947-2)
0 kA
Rated short-circuit breaking capacity (EN 61009)
6 kA
Rated short-circuit breaking capacity (EN 61009-1)
6 kA
Rated short-circuit breaking capacity (IEC 60947-2)
0 kA
Surge current capacity
0.25 kA
Disconnection characteristic
Undelayed
Pollution degree
2
Technical Data - Mechanical
Width in number of modular spacings
2
Built-in depth
69.5 mm
Degree of protection
IP20
Connectable conductor cross section (solid-core) - min
1 mm²
Connectable conductor cross section (solid-core) - max
25 mm²
Connectable conductor cross section (multi-wired) - min
1 mm²
Connectable conductor cross section (multi-wired) - max
25 mm²
Design verification as per IEC/EN 61439 - technical data
Ambient operating temperature - max
40 °C
Ambient operating temperature - min
-25 °C
Additional information
Current limiting class
3
Features
Concurrently switching N-neutral

Technical data ETIM 8.0

Circuit breakers and fuses (EG000020) / Earth leakage circuit breaker (EC000905)
Electric engineering, automation, process control engineering / Electrical installation, device / Residual current protection system / MCB/RCCB combination ([email protected] [AFZ810015])
Number of poles (total)
2
Number of protected poles
1
Rated voltage
230 V
Rated insulation voltage Ui
500 V
Rated impulse withstand voltage Uimp
4 kV
Rated current
13 A
Rated fault current
0.03 A
Leakage current type
A
Current limiting class
3
Rated short-circuit breaking capacity according to EN 61009
6 kA
Rated short-circuit breaking capacity according to IEC 60947-2
0 kA
Rated short-circuit breaking capacity Icn according to EN 61009-1
6 kA
Disconnection characteristic
Undelayed
Surge current capacity
0.25 kA
Voltage type
AC
Frequency
50 Hz
Release characteristic
B
Concurrently switching neutral conductor
Yes
With interlocking device
No
Over voltage category
3
Pollution degree
2
Ambient temperature during operating
-25 - 40 °C
Width in number of modular spacings
2
Built-in depth
69.5 mm
Flush-mounted installation
No
Anti-nuisance tripping version
No
Degree of protection (IP)
IP20
Connectable conductor cross section solid-core
1 - 25 mm²
Connectable conductor cross section multi-wired
1 - 25 mm²