EATON - MOELLER 40071353585 40071353585 EATON ELECTRIC Compact housing for BI-SKAP with insert View larger
Images are for illustrative purposes only. Please refer to data sheet for details

40071353585 EATON ELECTRIC Compact housing for BI-SKAP with insert

40071353585

40071353585

EATON - MOELLER

1 Pcs.

GuideLed SL Add-on housing for 130x2

Automation > Emergency luminaire
Central Battery System

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Compact housing for BI-SKAP with insert
EL-Nummer (Norway)
0001728060
Compact housing for additional application in combination with meter distributor I-SKAP
[

Design verification as per IEC/EN 61439

Technical data for design verification
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890Individual enclosure for wall mounting [PV]
35 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890Starting enclosure for wall mounting [PV]
33 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890Middle enclosure for wall mounting [PV]
31 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890Individual enclosure for wall mounting [PV]
71 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890Starting enclosure for wall mounting [PV]
66 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890Middle enclosure for wall mounting [PV]
61 W
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Not relevant to indoor installations.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply to enclosures without lifting aids.
10.2 Strength of materials and parts10.2.6 Mechanical impact
IK08
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
IP30
10.4 Clearances and creepage distances
Is the panel builder's responsibility.
10.5 Protection against electric shock
< 0.1 Ω; meets the product standard's requirements.
10.6 Incorporation of switching devices and components
Is the panel builder's responsibility.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Ui= 400 V AC
10.9 Insulation properties10.9.3 Impulse withstand voltage
2.5 kV
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Does not apply to metal enclosures.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
Meets the product standard's requirements.
,

Technical data ETIM 7.0

Distribution boards (EG000023) / Cable entry cabinet (EC000268)
Electric engineering, automation, process control engineering / Electrical installation, device / Electrical distribution system (incl. small distribution board) / Cable entry cabinet ([email protected] [ADI317007])
Mounting alongside enclosure
No
Mounting over enclosure
Yes
Mounting under enclosure
Yes
Number of poles
4
Max. cross section connection cable
16 mm²
Max. cross section incoming cable
50 mm²
Connection type
Clamp
Degree of protection (IP)
IP30
Height
385 mm
Width
475 mm
Depth
220 mm
]

ETIM for 40071353585 Luminaires (EC001957)
Feature Name Feature Value
Mounting method (EF000003)
Function (EF000030)
Suitable for labelling type (EF001277)
Type of indicator (EF001278)
With pictogram (EF011099)
Monitoring equipment (EF008091)
Suitable for standby switching (EF017055)
Suitable for continuous circuit (EF017056)
With remote switch connection (EF007947)
With remote control (EF000483)
Power supply system (EF000233)
Battery technology (EF004351)
Lamp type (EF002423)
With light source (EF005905)
Suitable for number of light sources (EF006436)
Lamp holder (EF000048)
Number of lighting heads (EF004258)
Housing material (EF001596)
RAL-number housing (EF012502)
Housing colour (EF000136)
Material cover (EF004284)
Voltage type (EF000187)
Nominal voltage (EF005127) None V
Nominal current (EF009345) None mA
Type of control gear (EF000381)
Exchangeable control gear (EF016286)
Light distributor (EF012170)
Max. number of luminaires per miniature circuit breaker B16 (MCB) (EF015534)
Energy efficiency class of the light source according to EU regulation 2019/2015 (EF016835)
Max. number of luminaires per miniature circuit breaker C16 (MCB) (EF015533)
Rated life time L70/B50 at 25 °C (EF011870) None h
Lumen maintenance at median useful life of 50,000 h at 25 °C ambient (tq) (EF015687) None %
Lumen maintenance at median useful life of 100,000 h at 25 °C ambient (tq) (EF015689) None %
Failure rate at median useful life of 50,000 h at 25 °C ambient (tq) (EF015691) None %
Failure rate at median useful life of 100,000 h at 25 °C ambient (tq) (EF015693) None %
Constant light output (CLO) (EF009482)
Degree of protection (IP) (EF005474)
Degree of protection (NEMA) (EF011959)
Impact strength (EF004293)
Protection class according to IEC 61140 (EF000004)
Luminaire with limited surface temperature, sign "D“ according to EN 60598-2-24 (EF006420)
Rated ambient temperature according to IEC 62722-2-1 (EF012090) None °C
Max. system power (EF009347) None W
Rated luminous flux according to IEC 62722-2-1 (EF009349) None lm
Luminous flux in standby mode (EF011954) None lm
Colour temperature (EF009346) None K
Power factor (EF025740)
Recognition distance (EF008732) None m
Nominal operation time (EF012518) None h
Flickering value Pst LM (EF015827)
Stroboscope effect value SVM (EF015828)
Width (EF000008) None mm
Height/depth (EF001456) None mm
Length (EF001438) None mm
Outer diameter (EF000015) None mm
Built-in width (EF000846) None mm
Built-in height/depth (EF023518) None mm
Built-in length (EF004265) None mm
Built-in diameter (EF000943) None mm
Type of wiring (EF011868)
Number of poles (EF001391)
Conductor cross section (EF000085) None mm²
Connection type (EF000124)

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.