View larger
SPX400A0-4A2N1 125428 Y7-125428 EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, 250 kW, IP00, OL..
SPX400A0-4A2N1
125428
Y7-125428
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Eaton Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Providing heavy-duty motor control, the Eaton Moeller SPX400A0-4A2N1 variable frequency drive manages large-scale industrial applications and high-power electrical loads. These drives are commonly deployed in manufacturing plants and municipal facilities to control large pumps, compressors, and conveyors. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 320 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 590 A
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 1
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 1
- Number of digital inputs (EF001992): 6
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
- Supporting protocol for TCP/IP (EF003050): Yes
More info
▲General specifications
Safety: EN 61800-5-1: 2003
UL report applies to both US and Canada
UL 508C
UL File No.: E134360
RoHS, ISO 9001
CUL
Specification for general requirements: IEC/EN 61800-2
Certified by UL for use in Canada
DNV
CE
CSA-C22.2 No. 14
RCM
CSA Class No.: 3211-06
IEC/EN 61800-3
IEC/EN61800-3
IEC/EN61800-5
UL
General
NEMA Other
Internal DC link
PC connection
IGBT inverter
Control unit
Climatic environmental conditions
Max. 1000 m
Max. 3000 m
Main circuit
U/f control
Optional: Vector control with feedback (CLV)
500 V AC, 3-phase
400 V AC, 3-phase
500 V AC, 3-phase
400 V AC, 3-phase
Motor rating
Control circuit
Communication
BACnet/IP, optional
CANopen®, optional
LonWorks, optional
DeviceNet, optional
Modbus-TCP, optional
BACnet MS/TP, optional
EtherCAT, optional
Ethernet IP, optional
Modbus-RTU, optional
PROFINET, optional
LON
DeviceNet
Data-Highway
TCP/IP
CAN
Other bus systems