View larger
SPX125A1-4A1N1 125669 Y7-125669 EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, 90 kW, IP21, Rad..
SPX125A1-4A1N1
125669
Y7-125669
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Eaton Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller Variable frequency drive (part number SPX125A1-4A1N1) functions as an electronic motor controller designed to regulate the speed and torque of AC induction motors within industrial machine setups.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Max. output frequency (EF007350): 320 Hz
- Number of analogue outputs (EF001995): 1
- With control element (EF001538): No
- Application in industrial area permitted (EF007294): No
- Supporting protocol for TCP/IP (EF003050): No
- Supporting protocol for PROFIBUS (EF003052): No
- Supporting protocol for CAN (EF003053): No
- Supporting protocol for INTERBUS (EF003054): No
- Supporting protocol for ASI (EF003051): No
- Supporting protocol for KNX (EF003055): No
- Supporting protocol for Modbus (EF003057): No
- Supporting protocol for Data-Highway (EF003058): No
- Supporting protocol for DeviceNet (EF003059): No
- Supporting protocol for SUCONET (EF003060): No
More info
▲General specifications
CSA Class No.: 3211-06
CUL
UL File No.: E134360
UL 508C
RCM
UL report applies to both US and Canada
IEC/EN61800-5
DNV
IEC/EN 61800-3
Specification for general requirements: IEC/EN 61800-2
RoHS, ISO 9001
Safety: EN 61800-5-1: 2003
UL Category Control No.: NMMS, NMMS2, NMMS7. NMMS8
UL
CE
Certified by UL for use in Canada
CSA-C22.2 No. 14
General
NEMA Other
Radio interference suppression filter
IGBT inverter
DC link choke
Internal DC link
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
Max. 3000 m
Main circuit
U/f control
Optional: Vector control with feedback (CLV)
480 V AC, 3-phase
500 V AC, 3-phase
480 V AC, 3-phase
400 V AC, 3-phase
Motor rating
Control circuit
Communication
BACnet/IP, optional
CANopen®, optional
Modbus-TCP, optional
PROFIBUS-DP
DeviceNet, optional
BACnet MS/TP, optional
EtherCAT, optional
Ethernet IP, optional
Modbus-RTU, optional
PROFINET, optional