View larger
SPX015A2-4A1B1 125664 Y7-125664 EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, 11 kW, IP54, Rad..
SPX015A2-4A1B1
125664
Y7-125664
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Eaton Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
SPX015A2-4A1B1 125664 Y7-125664 EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, 11 kW, IP54, Rad.. functions as a variable frequency drive used to govern electric motor performance by adjusting frequency and voltage parameters dynamically. Engineers install these devices in automation systems to improve process control, reduce energy consumption, and manage acceleration curves. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Max. output frequency (EF007350): 320 Hz
- Number of analogue outputs (EF001995): 1
- With control element (EF001538): No
- Application in industrial area permitted (EF007294): No
- Supporting protocol for TCP/IP (EF003050): No
- Supporting protocol for PROFIBUS (EF003052): No
- Supporting protocol for CAN (EF003053): No
- Supporting protocol for INTERBUS (EF003054): No
- Supporting protocol for ASI (EF003051): No
- Supporting protocol for KNX (EF003055): No
- Supporting protocol for Modbus (EF003057): No
- Supporting protocol for Data-Highway (EF003058): No
- Supporting protocol for DeviceNet (EF003059): No
- Supporting protocol for SUCONET (EF003060): No
More info
▲General specifications
CUL
DNV
RoHS, ISO 9001
Specification for general requirements: IEC/EN 61800-2
UL report applies to both US and Canada
IEC/EN 61800-3
UL 508C
Safety: EN 61800-5-1: 2003
UL
UL Category Control No.: NMMS, NMMS2, NMMS7. NMMS8
IEC/EN61800-5
RCM
UL File No.: E134360
CE
Certified by UL for use in Canada
CSA-C22.2 No. 14
IEC/EN61800-3
General
NEMA Other
Internal DC link
Radio interference suppression filter
IGBT inverter
DC link choke
Brake chopper
Climatic environmental conditions
Max. 3000 m
Above 1000 m with 1 % performance reduction per 100 m
Main circuit
Sensorless vector control (SLV)
Optional: Vector control with feedback (CLV)
480 V AC, 3-phase
500 V AC, 3-phase
500 V AC, 3-phase
400 V AC, 3-phase
Motor rating
Control circuit
Communication
PROFIBUS-DP
CANopen®, optional
BACnet/IP, optional
Modbus-TCP, optional
LonWorks, optional
BACnet MS/TP, optional
EtherCAT, optional
Ethernet IP, optional
Modbus-RTU, optional
PROFINET, optional