View larger
SPX005A1-5A4N1 125241 Y7-125241 EATON ELECTRIC Variable frequency drive, 600 V AC, 3-phase, 5.5 kW, IP21, Ra..
SPX005A1-5A4N1
125241
Y7-125241
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Eaton Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller variable frequency drive SPX005A1-5A4N1 (125241) functions as an industrial power conversion unit designed to adjust motor velocities for optimized manufacturing processes. These drives enable seamless speed modulation across varied heavy-duty commercial applications.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 525 V
- Mains frequency (EF006783): 50/60 Hz
- Max. output frequency (EF007350): 320 Hz
- Number of analogue outputs (EF001995): 1
- With control element (EF001538): No
- Application in industrial area permitted (EF007294): No
- Supporting protocol for TCP/IP (EF003050): No
- Supporting protocol for PROFIBUS (EF003052): No
- Supporting protocol for CAN (EF003053): No
- Supporting protocol for INTERBUS (EF003054): No
- Supporting protocol for ASI (EF003051): No
- Supporting protocol for KNX (EF003055): No
- Supporting protocol for Modbus (EF003057): No
- Supporting protocol for Data-Highway (EF003058): No
- Supporting protocol for DeviceNet (EF003059): No
- Supporting protocol for SUCONET (EF003060): No
More info
▲General specifications
IEC/EN 61800-3
RCM
UL Category Control No.: NMMS, NMMS2, NMMS7. NMMS8
UL File No.: E134360
UL report applies to both US and Canada
RoHS, ISO 9001
Specification for general requirements: IEC/EN 61800-2
UL
CUL
IEC/EN61800-3
Safety: EN 61800-5-1: 2003
UL 508C
CSA Class No.: 3211-06
DNV
Certified by UL for use in Canada
IEC/EN61800-5
CSA-C22.2 No. 14
General
NEMA Other
IGBT inverter
DC link choke
Radio interference suppression filter
OLED display
Climatic environmental conditions
Above 1000 m with 1 % performance reduction per 100 m
Max. 3000 m
Main circuit
U/f control
Optional: Vector control with feedback (CLV)
690 V AC, 3-phase
600 V AC, 3-phase
Motor rating
Control circuit
Communication
LonWorks, optional
Modbus-TCP, optional
BACnet/IP, optional
CANopen®, optional
DeviceNet, optional
BACnet MS/TP, optional
EtherCAT, optional
Ethernet IP, optional
Modbus-RTU, optional