View larger
DA1-345D8FB-B6SC 169383 Y7-169383 EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, 5.8 A, 2.2 kW,..
DA1-345D8FB-B6SC
169383
Y7-169383
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered by Eaton Moeller, the DA1-345D8FB-B6SC is a variable frequency drive built to govern electric motor speeds across complex automated workflows. Variable frequency drives are standard components in mechanical engineering, allowing operators to fine-tune rotational speed and maintain steady torque levels under changing loads.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 5.8 A
- Power consumption (EF000346): 101.2 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 5
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
Certified by UL for use in Canada
CUL
IEC/EN61800-3
Safety: EN 61800-5-1: 2003
UL
UL File No.: E172143
UL Category Control No.: NMMS, NMMS7
EAC
UkrSEPRO
UL 508C
IEC/EN 61800-3
IEC/EN61800-5
RCM
Specification for general requirements: IEC/EN 61800-2
CE
CSA-C22.2 No. 14
UL report applies to both US and Canada
General
C3 ≤ 25 m, Radio interference level, maximum motor cable length
200 m, screened, with motor choke, maximum permissible, Motor feeder
C2 ≤ 5 m, Radio interference level, maximum motor cable length
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
100 m, screened, maximum permissible, Motor feeder
PROFIBUS, optional
Modbus RTU, built in
Modbus-TCP, optional
EtherCAT, optional
PROFINET, optional
OP-Bus (RS485), built in
DeviceNet, optional
CANopen®, built in
NEMA 4X
Breaking resistance
OLED display
Internal DC link
PC connection
Radio interference suppression filter
Brake chopper
Additional PCB protection
IGBT inverter
Control unit
CAN
Other bus systems
PROFINET IO
DeviceNet
MODBUS
PROFIBUS
TCP/IP
Climatic environmental conditions
Max. 1000 m
Above 1000 m with 1 % derating per 100 m
Main circuit
38 W at 25% current and 50% speed
43 W at 50% current and 0% speed
47 W at 50% current and 50% speed
51 W at 100% current and 0% speed
57 W at 50% current and 90% speed
66 W at 100% current and 50% speed
81 W at 100% current and 90% speed
Speed control with slip compensation
U/f control
Optional: Vector control with feedback (CLV)
400 V AC, 3-phase
400 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 30 % MN, Standard - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit