View larger
DA1-344D1FB-B6SC 169381 Y7-169381 EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, 4.1 A, 1.5 kW,..
DA1-344D1FB-B6SC
169381
Y7-169381
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Serving as a reliable variable frequency drive, the Eaton Moeller DA1-344D1FB-B6SC manages AC motor operations in diverse plant environments. Manufacturers deploy these units to protect equipment from mechanical stress, reduce energy consumption, and achieve precise speed control in automated production systems.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 4.1 A
- Power consumption (EF000346): 76.5 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 5
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN61800-3
UL Category Control No.: NMMS, NMMS7
CUL
Safety: EN 61800-5-1: 2003
IEC/EN61800-5
RCM
CE
UL
RoHS, ISO 9001
Specification for general requirements: IEC/EN 61800-2
Certified by UL for use in Canada
CSA-C22.2 No. 14
IEC/EN 61800-3
EAC
UL 508C
UL File No.: E172143
UL report applies to both US and Canada
General
200 m, screened, with motor choke, maximum permissible, Motor feeder
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
100 m, screened, maximum permissible, Motor feeder
150 m, unscreened, maximum permissible, Motor feeder
C2 ≤ 5 m, Radio interference level, maximum motor cable length
PROFIBUS, optional
DeviceNet, optional
Modbus-TCP, optional
Modbus RTU, built in
CANopen®, built in
Ethernet IP, optional
PROFINET, optional
EtherCAT, optional
NEMA 4X
Control unit
Radio interference suppression filter
PC connection
Brake chopper
Breaking resistance
OLED display
Local controls
IGBT inverter
Internal DC link
PROFINET IO
DeviceNet
PROFIBUS
EtherNet/IP
Other bus systems
CAN
TCP/IP
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Climatic environmental conditions
Max. 4000 m
Above 1000 m with 1 % derating per 100 m
Main circuit
32 W at 25% current and 50% speed
34 W at 50% current and 0% speed
38 W at 50% current and 50% speed
43 W at 100% current and 0% speed
44 W at 50% current and 90% speed
56 W at 100% current and 50% speed
58 W at 100% current and 90% speed
U/f control
Sensorless vector control (SLV)
Optional: Vector control with feedback (CLV)
480 V AC, 3-phase
480 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie, variable, DC - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit