Eaton Moeller DA1-344D1FB-B66C functions as a variable frequency drive built to regulate three-phase motor speeds and enhance efficiency in manufacturing plants. By modifying voltage and frequency parameters dynamically, such units protect machinery from mechanical shock and optimize throughput. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 4.1 A
- Power consumption (EF000346): 76.5 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 5
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL File No.: E172143
CSA-C22.2 No. 14
CUL
UL 508C
Certified by UL for use in Canada
RCM
RoHS, ISO 9001
Safety: EN 61800-5-1: 2003
UL
IEC/EN 61800-3
IEC/EN61800-3
Specification for general requirements: IEC/EN 61800-2
EAC
IEC/EN61800-5
UL Category Control No.: NMMS, NMMS7
UL report applies to both US and Canada
CE
General
100 m, screened, maximum permissible, Motor feeder
C3 ≤ 25 m, Radio interference level, maximum motor cable length
200 m, screened, with motor choke, maximum permissible, Motor feeder
C2 ≤ 5 m, Radio interference level, maximum motor cable length
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
Modbus-TCP, optional
Ethernet IP, optional
PROFIBUS, optional
EtherCAT, optional
PROFINET, optional
Modbus RTU, built in
CANopen®, built in
OP-Bus (RS485), built in
IP66
Radio interference suppression filter
OLED display
Breaking resistance
IGBT inverter
Control unit
Brake chopper
Additional PCB protection
Internal DC link
DeviceNet
PROFIBUS
EtherNet/IP
CAN
PROFINET IO
Other bus systems
TCP/IP
Climatic environmental conditions
Max. 4000 m
Above 1000 m with 1 % derating per 100 m
Main circuit
32 W at 25% current and 50% speed
34 W at 50% current and 0% speed
38 W at 50% current and 50% speed
43 W at 100% current and 0% speed
44 W at 50% current and 90% speed
56 W at 100% current and 50% speed
58 W at 100% current and 90% speed
Optional: Vector control with feedback (CLV)
Speed control with slip compensation
Sensorless vector control (SLV)
480 V AC, 3-phase
480 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 30 % MN, Standard - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit