View larger
DA1-342D2FB-B66C 169378 Y7-169378 EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, 2.2 A, 0.75 kW..
DA1-342D2FB-B66C
169378
Y7-169378
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
DA1-342D2FB-B66C Eaton Moeller variable frequency drive regulates motor velocity and torque in complex industrial automation machinery. Frequency converters help minimize mechanical stress and improve overall system efficiency.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 2.2 A
- Power consumption (EF000346): 63.75 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 5
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
CSA-C22.2 No. 14
UkrSEPRO
Certified by UL for use in Canada
EAC
CUL
Safety: EN 61800-5-1: 2003
UL Category Control No.: NMMS, NMMS7
UL
UL File No.: E172143
IEC/EN 61800-3
IEC/EN61800-3
UL 508C
RCM
IEC/EN61800-5
UL report applies to both US and Canada
Specification for general requirements: IEC/EN 61800-2
RoHS, ISO 9001
General
C3 ≤ 25 m, Radio interference level, maximum motor cable length
C2 ≤ 5 m, Radio interference level, maximum motor cable length
100 m, screened, maximum permissible, Motor feeder
150 m, unscreened, maximum permissible, Motor feeder
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
DeviceNet, optional
Modbus RTU, built in
OP-Bus (RS485), built in
Modbus-TCP, optional
Ethernet IP, optional
CANopen®, built in
PROFIBUS, optional
PROFINET, optional
NEMA 4X
Internal DC link
Additional PCB protection
Control unit
PC connection
Radio interference suppression filter
Breaking resistance
IGBT inverter
Brake chopper
Other bus systems
DeviceNet
MODBUS
EtherNet/IP
CAN
PROFIBUS
TCP/IP
Climatic environmental conditions
Max. 4000 m
Max. 1000 m
Main circuit
20 W at 50% current and 0% speed
21 W at 25% current and 50% speed
21 W at 50% current and 50% speed
23 W at 50% current and 90% speed
26 W at 100% current and 0% speed
26 W at 100% current and 50% speed
33 W at 100% current and 90% speed
Optional: Vector control with feedback (CLV)
Sensorless vector control (SLV)
Speed control with slip compensation
480 V AC, 3-phase
480 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie, variable, DC - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit