View larger
DA1-34072FB-B55C 169395 Y7-169395 EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, 72 A, 37 kW, I..
DA1-34072FB-B55C
169395
Y7-169395
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller manufactured the DA1-34072FB-B55C variable frequency drive to deliver heavy-duty motor control and speed regulation in demanding factory settings. Industrial engineers deploy these robust units to optimize energy use and manage operational parameters on large automated machinery.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 72 A
- Power consumption (EF000346): 925 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 5
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN61800-3
IEC/EN 61800-3
IEC/EN61800-5
UL File No.: E172143
RoHS, ISO 9001
UL
RCM
CSA-C22.2 No. 14
CE
CUL
DNV
Safety: EN 61800-5-1: 2003
UkrSEPRO
UL 508C
Specification for general requirements: IEC/EN 61800-2
UL Category Control No.: NMMS, NMMS7
EAC
UL report applies to both US and Canada
General
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
C3 ≤ 25 m, Radio interference level, maximum motor cable length
200 m, screened, with motor choke, maximum permissible, Motor feeder
C2 ≤ 5 m, Radio interference level, maximum motor cable length
150 m, unscreened, maximum permissible, Motor feeder
Ethernet IP, optional
PROFIBUS, optional
PROFINET, optional
SmartWire-DT, optional
EtherCAT, optional
CANopen®, built in
Modbus-TCP, optional
OP-Bus (RS485), built in
Modbus RTU, built in
In conjunction with DX-NET-SWD1 SmartWire DT module
IP55
Control unit
Breaking resistance
Radio interference suppression filter
Brake chopper
Internal DC link
IGBT inverter
DC link choke
Additional PCB protection
PC connection
Other bus systems
PROFIBUS
EtherNet/IP
CAN
PROFINET IO
DeviceNet
TCP/IP
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Max. 4000 m
Main circuit
280 W at 25% current and 0% speed
280 W at 25% current and 50% speed
370 W at 50% current and 0% speed
410 W at 50% current and 50% speed
460 W at 50% current and 90% speed
830 W at 100% current and 50% speed
990 W at 100% current and 90% speed
Sensorless vector control (SLV)
Speed control with slip compensation
Optional: Vector control with feedback (CLV)
400 V AC, 3-phase
480 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit
Max. 30 % MN, Standard - Main circuit