DA1-34046FB-B55C 169393 Y7-169393 EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, 46 A, 22 kW, I..
DA1-34046FB-B55C
169393
Y7-169393
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This Eaton Moeller DA1-34046FB-B55C variable frequency drive is a motor control device utilized to regulate the operational speed and torque of three-phase electrical motors in industrial automation systems. Frequency converters improve overall energy efficiency and process precision by matching motor output dynamically to changing load demands.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 46 A
- Power consumption (EF000346): 506 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 5
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
CSA-C22.2 No. 14
UL
IEC/EN61800-5
EAC
CE
UkrSEPRO
Safety: EN 61800-5-1: 2003
UL File No.: E172143
CUL
UL report applies to both US and Canada
Certified by UL for use in Canada
IEC/EN61800-3
DNV
RCM
Specification for general requirements: IEC/EN 61800-2
RoHS, ISO 9001
UL Category Control No.: NMMS, NMMS7
IEC/EN 61800-3
General
100 m, screened, maximum permissible, Motor feeder
C3 ≤ 25 m, Radio interference level, maximum motor cable length
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
C2 ≤ 5 m, Radio interference level, maximum motor cable length
150 m, unscreened, maximum permissible, Motor feeder
PROFINET, optional
Ethernet IP, optional
PROFIBUS, optional
DeviceNet, optional
OP-Bus (RS485), built in
Modbus RTU, built in
Modbus-TCP, optional
EtherCAT, optional
SmartWire-DT, optional
In conjunction with DX-NET-SWD1 SmartWire DT module
IP55
OLED display
Radio interference suppression filter
Additional PCB protection
Breaking resistance
PC connection
IGBT inverter
Brake chopper
Internal DC link
PROFIBUS
EtherNet/IP
PROFINET IO
DeviceNet
MODBUS
Other bus systems
TCP/IP
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Climatic environmental conditions
Max. 4000 m
Max. 1000 m
Main circuit
231 W at 25% current and 50% speed
261 W at 50% current and 0% speed
303 W at 50% current and 50% speed
350 W at 50% current and 90% speed
447 W at 100% current and 0% speed
527 W at 100% current and 50% speed
614 W at 100% current and 90% speed
Sensorless vector control (SLV)
Speed control with slip compensation
Optional: Vector control with feedback (CLV)
480 V AC, 3-phase
480 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie, variable, DC - Main circuit
Max. 30 % MN, Standard - Main circuit