View larger
DA1-34039FB-B55C 169392 Y7-169392 EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, 39 A, 18.5 kW,..
DA1-34039FB-B55C
169392
Y7-169392
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Electric variable frequency drive delivers precise speed control for three-phase AC motors in demanding industrial environments. Industrial frequency converters dynamically adjust output frequency and voltage to optimize mechanical performance and reduce energy consumption.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 39 A
- Power consumption (EF000346): 444 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 5
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
DNV
UkrSEPRO
UL
UL Category Control No.: NMMS, NMMS7
UL 508C
IEC/EN61800-3
CUL
IEC/EN61800-5
RCM
Safety: EN 61800-5-1: 2003
EAC
RoHS, ISO 9001
UL File No.: E172143
CSA-C22.2 No. 14
IEC/EN 61800-3
Certified by UL for use in Canada
Specification for general requirements: IEC/EN 61800-2
UL report applies to both US and Canada
General
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
100 m, screened, maximum permissible, Motor feeder
150 m, unscreened, maximum permissible, Motor feeder
C2 ≤ 5 m, Radio interference level, maximum motor cable length
200 m, screened, with motor choke, maximum permissible, Motor feeder
PROFINET, optional
SmartWire-DT, optional
PROFIBUS, optional
OP-Bus (RS485), built in
CANopen®, built in
DeviceNet, optional
Modbus-TCP, optional
Modbus RTU, built in
EtherCAT, optional
In conjunction with DX-NET-SWD1 SmartWire DT module
IP55
Internal DC link
Additional PCB protection
Breaking resistance
OLED display
Control unit
Radio interference suppression filter
IGBT inverter
PC connection
PROFIBUS
CAN
PROFINET IO
Other bus systems
EtherNet/IP
DeviceNet
TCP/IP
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Climatic environmental conditions
Max. 4000 m
Above 1000 m with 1 % derating per 100 m
Main circuit
205 W at 25% current and 50% speed
221 W at 50% current and 0% speed
246 W at 50% current and 50% speed
296 W at 50% current and 90% speed
371 W at 100% current and 0% speed
428 W at 100% current and 50% speed
504 W at 100% current and 90% speed
Speed control with slip compensation
Optional: Vector control with feedback (CLV)
U/f control
400 V AC, 3-phase
400 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 30 % MN, Standard - Main circuit
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit