View larger
DA1-34024FB-B55C 169390 Y7-169390 EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, 24 A, 11 kW, I..
DA1-34024FB-B55C
169390
Y7-169390
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Electric Variable frequency drive, 400 V AC, 3-phase, 24 A, 11 kW, I.. provides advanced motor control capabilities to optimize productivity across automated production lines. Modern variable frequency drives regulate AC motor speeds dynamically to match fluctuating load requirements.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 380 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 500 V
- Nominal output current I2N (EF009561): 24 A
- Power consumption (EF000346): 297 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 5
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL report applies to both US and Canada
Specification for general requirements: IEC/EN 61800-2
DNV
UL Category Control No.: NMMS, NMMS7
UL
CSA-C22.2 No. 14
UkrSEPRO
EAC
UL 508C
Certified by UL for use in Canada
IEC/EN61800-5
UL File No.: E172143
IEC/EN 61800-3
RCM
IEC/EN61800-3
CUL
RoHS, ISO 9001
Safety: EN 61800-5-1: 2003
General
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
C2 ≤ 5 m, Radio interference level, maximum motor cable length
C3 ≤ 25 m, Radio interference level, maximum motor cable length
150 m, unscreened, maximum permissible, Motor feeder
100 m, screened, maximum permissible, Motor feeder
Ethernet IP, optional
CANopen®, built in
OP-Bus (RS485), built in
Modbus-TCP, optional
SmartWire-DT, optional
PROFIBUS, optional
DeviceNet, optional
Modbus RTU, built in
PROFINET, optional
Yes
NEMA 12
Control unit
Internal DC link
Additional PCB protection
Breaking resistance
IGBT inverter
Brake chopper
Radio interference suppression filter
PC connection
Other bus systems
EtherNet/IP
DeviceNet
CAN
MODBUS
PROFINET IO
TCP/IP
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Climatic environmental conditions
Max. 1000 m
Max. 4000 m
Main circuit
139 W at 25% current and 50% speed
156 W at 50% current and 0% speed
162 W at 50% current and 50% speed
178 W at 50% current and 90% speed
234 W at 100% current and 0% speed
258 W at 100% current and 50% speed
284 W at 100% current and 90% speed
Speed control with slip compensation
Optional: Vector control with feedback (CLV)
U/f control
400 V AC, 3-phase
480 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie, variable, DC - Main circuit
Max. 30 % MN, Standard - Main circuit