Eaton Moeller DA1-327D0FB-B6SC is a variable frequency drive that provides seamless control over motor speed and torque characteristics in industrial automation setups. Industrial drives are essential for managing dynamic electrical loads, lowering power consumption, and extending the service life of connected machinery. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 200 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 250 V
- Nominal output current I2N (EF009561): 7 A
- Power consumption (EF000346): 61.5 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 5
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
Certified by UL for use in Canada
UkrSEPRO
UL File No.: E172143
IEC/EN 61800-3
EAC
CE
IEC/EN61800-3
CUL
RoHS, ISO 9001
UL 508C
UL
RCM
CSA-C22.2 No. 14
IEC/EN61800-5
Safety: EN 61800-5-1: 2003
UL Category Control No.: NMMS, NMMS7
UL report applies to both US and Canada
General
100 m, screened, maximum permissible, Motor feeder
200 m, screened, with motor choke, maximum permissible, Motor feeder
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
C2 ≤ 5 m, Radio interference level, maximum motor cable length
150 m, unscreened, maximum permissible, Motor feeder
OP-Bus (RS485), built in
EtherCAT, optional
DeviceNet, optional
PROFIBUS, optional
PROFINET, optional
CANopen®, built in
Modbus RTU, built in
Ethernet IP, optional
NEMA 4X
Additional PCB protection
PC connection
IGBT inverter
Control unit
Brake chopper
Internal DC link
OLED display
Radio interference suppression filter
Local controls
EtherNet/IP
Other bus systems
CAN
PROFINET IO
PROFIBUS
MODBUS
TCP/IP
Climatic environmental conditions
Max. 1000 m
Above 1000 m with 1 % derating per 100 m
Main circuit
35 W at 25% current and 50% speed
36 W at 50% current and 0% speed
43 W at 50% current and 50% speed
51 W at 100% current and 0% speed
51 W at 50% current and 90% speed
60 W at 100% current and 50% speed
71 W at 100% current and 90% speed
Speed control with slip compensation
Sensorless vector control (SLV)
Optional: Vector control with feedback (CLV)
240 V AC, 3-phase
230 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 30 % MN, Standard - Main circuit