View larger
DA1-32061FB-B55C 169364 Y7-169364 EATON ELECTRIC Variable frequency drive, 230 V AC, 3-phase, 61 A, 15 kW, I..
DA1-32061FB-B55C
169364
Y7-169364
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller DA1-32061FB-B55C variable frequency drive functions as a specialized Eaton Moeller frequency converter designed to adjust the operating speed of three-phase electric motors. By matching motor speed to real-time load requirements, such devices reduce mechanical wear and optimize electrical efficiency across manufacturing lines and automated systems.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 200 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 250 V
- Nominal output current I2N (EF009561): 61 A
- Power consumption (EF000346): 345 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 5
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
RoHS, ISO 9001
UL report applies to both US and Canada
CSA-C22.2 No. 14
Specification for general requirements: IEC/EN 61800-2
CUL
UL 508C
Certified by UL for use in Canada
IEC/EN61800-5
DNV
UL
CE
IEC/EN61800-3
UkrSEPRO
UL File No.: E172143
Safety: EN 61800-5-1: 2003
UL Category Control No.: NMMS, NMMS7
EAC
IEC/EN 61800-3
General
100 m, screened, maximum permissible, Motor feeder
200 m, screened, with motor choke, maximum permissible, Motor feeder
150 m, unscreened, maximum permissible, Motor feeder
C2 ≤ 5 m, Radio interference level, maximum motor cable length
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
Modbus RTU, built in
OP-Bus (RS485), built in
PROFINET, optional
CANopen®, built in
PROFIBUS, optional
SmartWire-DT, optional
Ethernet IP, optional
DeviceNet, optional
Modbus-TCP, optional
Yes
NEMA 12
Brake chopper
DC link choke
Breaking resistance
Control unit
OLED display
Additional PCB protection
PC connection
Internal DC link
IGBT inverter
EtherNet/IP
PROFINET IO
PROFIBUS
DeviceNet
CAN
Other bus systems
TCP/IP
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Climatic environmental conditions
Above 1000 m with 1 % derating per 100 m
Max. 1000 m
Main circuit
210 W at 25% current and 50% speed
240 W at 50% current and 0% speed
320 W at 50% current and 50% speed
380 W at 50% current and 90% speed
430 W at 100% current and 0% speed
560 W at 100% current and 50% speed
700 W at 100% current and 90% speed
Optional: Vector control with feedback (CLV)
U/f control
Speed control with slip compensation
240 V AC, 3-phase
240 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit
Max. 30 % MN, Standard - Main circuit