View larger
DA1-32011FB-A20C 169093 Y7-169093 EATON ELECTRIC Variable frequency drive, 230 V AC, 3-phase, 10.5 A, 2.2 kW..
DA1-32011FB-A20C
169093
Y7-169093
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller DA1-32011FB-A20C is a versatile variable frequency drive engineered for precise speed and torque regulation across various automated industrial processes. Such drives convert standard electrical supplies into adjustable voltage and frequency outputs to optimize motor performance. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 200 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 3
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 250 V
- Nominal output current I2N (EF009561): 10.5 A
- Power consumption (EF000346): 90.2 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 5
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
UL report applies to both US and Canada
EAC
IEC/EN61800-3
IEC/EN61800-5
RoHS, ISO 9001
UL 508C
Safety: EN 61800-5-1: 2003
Certified by UL for use in Canada
CUL
CE
IEC/EN 61800-3
UL Category Control No.: NMMS, NMMS7
Specification for general requirements: IEC/EN 61800-2
UkrSEPRO
CSA-C22.2 No. 14
RCM
UL
General
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
C2 ≤ 5 m, Radio interference level, maximum motor cable length
C3 ≤ 25 m, Radio interference level, maximum motor cable length
100 m, screened, maximum permissible, Motor feeder
200 m, screened, with motor choke, maximum permissible, Motor feeder
OP-Bus (RS485), built in
Modbus-TCP, optional
EtherCAT, optional
PROFIBUS, optional
DeviceNet, optional
PROFINET, optional
CANopen®, built in
Ethernet IP, optional
Modbus RTU, built in
Yes
NEMA Other
PC connection
IGBT inverter
7-digital display assembly
Radio interference suppression filter
Breaking resistance
Brake chopper
Control unit
Internal DC link
Other bus systems
EtherNet/IP
PROFINET IO
MODBUS
CAN
DeviceNet
TCP/IP
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Climatic environmental conditions
Max. 1000 m
Above 1000 m with 1 % derating per 100 m
Main circuit
42 W at 50% current and 0% speed
43 W at 25% current and 0% speed
51 W at 25% current and 50% speed
62 W at 50% current and 50% speed
74 W at 100% current and 0% speed
74 W at 50% current and 90% speed
90 W at 100% current and 50% speed
Sensorless vector control (SLV)
Speed control with slip compensation
Optional: Vector control with feedback (CLV)
230 V AC, 3-phase
240 V AC, 3-phase
Motor rating
Apparent power
Braking function
Max. 100 % of rated operational current Ie with external braking resistor - Main circuit
Max. 100 % of rated operational current Ie, variable, DC - Main circuit