View larger
DA1-12011FB-A20C 169084 Y7-169084 EATON ELECTRIC Variable frequency drive, 230 V AC, 1-phase, 10.5 A, 2.2 kW..
DA1-12011FB-A20C
169084
Y7-169084
EATON - MOELLER
1 Pcs.
Automation > Frequency converter less than 1 kV
Power XL Frequency Converters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Serving as an efficient motor speed regulator, the Eaton Moeller DA1-12011FB-A20C variable frequency drive converts incoming electrical inputs to drive three-phase loads with high accuracy. Such devices are widely utilized in factory automation to control fluid flow, conveyor speeds, and mechanical positioning.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Mains voltage (EF006780): 200 V
- Mains frequency (EF006783): 50/60 Hz
- Number of phases input (EF007117): 1
- Number of phases output (EF006998): 3
- Max. output frequency (EF007350): 500 Hz
- Max. output voltage (EF009560): 250 V
- Nominal output current I2N (EF009561): 10.5 A
- Power consumption (EF000346): 103.4 W
- Relative symmetric net frequency tolerance (EF007454): 10 %
- Relative symmetric net voltage tolerance (EF007453): 10 %
- Number of analogue outputs (EF001995): 2
- Number of analogue inputs (EF001994): 2
- Number of digital outputs (EF001993): 2
- Number of digital inputs (EF001992): 5
- With control element (EF001538): Yes
- Application in industrial area permitted (EF007294): Yes
More info
▲General specifications
IEC/EN 61800-3
Safety: EN 61800-5-1: 2003
IEC/EN61800-3
UL 508C
CE
CSA-C22.2 No. 14
CUL
RCM
Specification for general requirements: IEC/EN 61800-2
UL Category Control No.: NMMS, NMMS7
UL
UL report applies to both US and Canada
IEC/EN61800-5
UkrSEPRO
Certified by UL for use in Canada
RoHS, ISO 9001
UL File No.: E172143
General
C2 ≤ 5 m, Radio interference level, maximum motor cable length
200 m, screened, with motor choke, maximum permissible, Motor feeder
100 m, screened, maximum permissible, Motor feeder
150 m, unscreened, maximum permissible, Motor feeder
300 m, unscreened, with motor choke, maximum permissible, Motor feeder
C1 ≤ 1 m, Radio interference level, maximum motor cable length
EtherCAT, optional
SmartWire-DT, optional
Ethernet IP, optional
PROFINET, optional
Modbus-TCP, optional
Modbus RTU, built in
CANopen®, built in
DeviceNet, optional
PROFIBUS, optional
Yes
NEMA Other
Radio interference suppression filter
Additional PCB protection
PC connection
Breaking resistance
Brake chopper
7-digital display assembly
IGBT inverter
Internal DC link
FS2
Other bus systems
PROFINET IO
PROFIBUS
DeviceNet
EtherNet/IP
MODBUS
TCP/IP
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Climatic environmental conditions
Max. 4000 m
Above 1000 m with 1 % derating per 100 m
Main circuit
119 W at 100% current and 50% speed
139 W at 100% current and 90% speed
44 W at 25% current and 0% speed
54 W at 50% current and 0% speed
62 W at 25% current and 50% speed
78 W at 50% current and 50% speed
80 W at 50% current and 90% speed
U/f control
Optional: Vector control with feedback (CLV)
Speed control with slip compensation
240 V AC, 3-phase
240 V AC, 1-phase
Motor rating
Apparent power
Braking function
Max. 30 % MN, Standard - Main circuit
Max. 100 % of rated operational current Ie, variable, DC - Main circuit