View larger
FRCDM-63/4/003-U 168640 EATON ELECTRIC Digital residual current circuit-breaker, 63A, 4p, 30mA, type U
FRCDM-63/4/003-U
168640
EATON - MOELLER
1 Pcs.
Automation > Residual current circuit breaker (RCCB)
Modular Switchgear – Industrial
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The FRCDM-63/4/003-U 168640 EATON ELECTRIC Digital residual current circuit-breaker, 63A, 4p, 30mA, type U is a digital residual current circuit-breaker that monitors line currents for differential faults and disconnects supply power to prevent hazardous shocks. These protective devices are routinely deployed in industrial and commercial distribution panels to maintain electrical safety standards and prevent insulation breakdown hazards.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of poles (EF001391): 4
- Rated voltage (EF000228): 415 V
- Rated current (EF000227): 63 A
- Rated fault current (EF002358): 0.03 A
- Rated insulation voltage Ui (EF001366): 440 V
- Rated impulse withstand voltage Uimp (EF011980): 4 kV
- Mounting method (EF000003): DIN rail
- Leakage current type (EF002560): A
- Selective protection (EF002561): No
- Short-time delayed tripping (EF003604): Yes
- Short-circuit breaking capacity (Icw) (EF002562): 10 kA
- Surge current capacity (EF002564): 3 kA
- With interlocking device (EF007385): Yes
- Frequency (EF005455): 50 Hz
- Additional equipment possible (EF008148): Yes
- Degree of protection (IP) (EF005474): IP20
More info
▲General specifications
EN45545-2
IEC 61373
Delivery program
Short time-delayed
Technical data - electrical
Technical data - electrical - dry auxiliary contact
Technical data - mechanical
DIN rail
IP20
Design verification as per IEC/EN 61439 - technical data
Design verification as per IEC/EN 61439
Additional information
Additional equipment possible
Selective protection
- Current test marks as per inscription
- Dry auxiliary contact: > 100,000 electrical switching operations per minute at 2 A 30 VDC resistive load
- Dry auxiliary contact: > 5 x 100,000 electrical switching operations per minute at 1 A 30 VDC resistive load
- Maximum operating temperature is 60 °C: Starting at 40 °C, the max. permissible continuous current decreases by 1.8% for every 1 °C
FRCdM
Residual current circuit-breakers, digital