View larger
FRCDM-63/4/003-G/B/60HZ 180424 Y7-180424 EATON ELECTRIC Digital residual current circuit-breaker, 63A, 4p, 3..
FRCDM-63/4/003-G/B/60HZ
180424
Y7-180424
EATON - MOELLER
1 Pcs.
Automation > Residual current circuit breaker (RCCB)
Modular Switchgear – Industrial
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller digital residual current circuit-breaker, part number FRCDM-63/4/003-G/B/60HZ, offers advanced earth fault monitoring for industrial electrical grids requiring precise leakage current detection. This digital protective device helps prevent dangerous fault conditions by disconnecting the supply when leakage parameters exceed safe thresholds.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of poles (EF001391): 4
- Rated voltage (EF000228): 415 V
- Rated current (EF000227): 63 A
- Rated fault current (EF002358): 0.03 A
- Rated insulation voltage Ui (EF001366): 440 V
- Rated impulse withstand voltage Uimp (EF011980): 4 kV
- Mounting method (EF000003): DIN rail
- Leakage current type (EF002560): B
- Selective protection (EF002561): No
- Short-time delayed tripping (EF003604): Yes
- Short-circuit breaking capacity (Icw) (EF002562): 10 kA
- Surge current capacity (EF002564): 3 kA
- Voltage type (EF000187): AC
- With interlocking device (EF007385): Yes
- Frequency (EF005455): 60 Hz
- Additional equipment possible (EF008148): Yes
More info
▲General specifications
IEC 61373
IEC/EN 61008
IEC/EN 62423
ÖVE E 8601
Delivery program
- Current test marks as per inscription
- Dry auxiliary contact: > 100,000 electrical switching operations per minute at 2 A 30 VDC resistive load
- Dry auxiliary contact: > 5 x 100,000 electrical switching operations per minute at 1 A 30 VDC resistive load
- Maximum operating temperature is 60 °C in accordance with the de-rating table
Technical data - electrical
Technical data - electrical - dry auxiliary contact
Technical data - mechanical
DIN rail
IP20, IP40 with suitable enclosure
Design verification as per IEC/EN 61439 - technical data
Design verification as per IEC/EN 61439
Additional information
Residual current circuit-breakers, digital
- FRCdM
- Residual current circuit-breakers, digital
- Type G/B (ÖVE E 8601)
FRCdM
Residual current circuit-breakers, digital