View larger
FRCDM-40/4/003-G/B+/60HZ 180422 Y7-180422 EATON ELECTRIC Digital residual current circuit-breaker, 40A, 4p, ..
FRCDM-40/4/003-G/B+/60HZ
180422
Y7-180422
EATON - MOELLER
1 Pcs.
Automation > Residual current circuit breaker (RCCB)
Modular Switchgear – Industrial
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Digital residual current circuit-breaker, 40A, 4p, .. manufactured by Eaton Moeller with part number FRCDM-40/4/003-G/B+/60HZ 180422 Y7-180422 EATON ELECTRIC provides advanced fault current monitoring for complex electrical installations. These specialized digital protection units are implemented in high-tech industrial environments to detect high-frequency and DC residual currents safely. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of poles (EF001391): 4
- Rated voltage (EF000228): 415 V
- Rated current (EF000227): 40 A
- Rated fault current (EF002358): 0.03 A
- Rated insulation voltage Ui (EF001366): 440 V
- Rated impulse withstand voltage Uimp (EF011980): 4 kV
- Mounting method (EF000003): DIN rail
- Leakage current type (EF002560): B+
- Selective protection (EF002561): No
- Short-time delayed tripping (EF003604): Yes
- Short-circuit breaking capacity (Icw) (EF002562): 10 kA
- Surge current capacity (EF002564): 3 kA
- Voltage type (EF000187): AC
- With interlocking device (EF007385): Yes
- Frequency (EF005455): 60 Hz
- Additional equipment possible (EF008148): Yes
More info
▲General specifications
IEC 61373
IEC/EN 61008
IEC/EN 62423
ÖVE E 8601
VDE 0664-400
Delivery program
Technical data - electrical
Technical data - electrical - dry auxiliary contact
Technical data - mechanical
Quick attachment with 2 latch positions for DIN-rail IEC/EN 60715
IP20, IP40 with suitable enclosure
Design verification as per IEC/EN 61439 - technical data
Design verification as per IEC/EN 61439
Additional information
Residual current circuit-breakers, digital
- Current test marks as per inscription
- Dry auxiliary contact: > 100,000 electrical switching operations per minute at 2 A 30 VDC resistive load
- Dry auxiliary contact: > 5 x 100,000 electrical switching operations per minute at 1 A 30 VDC resistive load
- Maximum operating temperature is 60 °C in accordance with the de-rating table
Residual current circuit-breakers, digital
Type G/B+ (ÖVE E 8601)