EATON - MOELLER FRBMM-D6/1N/001-A FRBMM-D6/1N/001-A 170916 Y7-170916 EATON ELECTRIC RCD/MCB combination switch, 6A, 10mA, miniature circuit-br.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

FRBMM-D6/1N/001-A 170916 Y7-170916 EATON ELECTRIC RCD/MCB combination switch, 6A, 10mA, miniature circuit-br..

FRBMM-D6/1N/001-A

170916

Y7-170916

EATON - MOELLER

1 Pcs.

RCD/MCB combination switch, 6A, 10mA, miniature circuit-br. type D trip characteristic, 1-phase+N, residual current circuit-br. trip characteristic: A FRBMM-D6/1N/001-A RCD/MCB combination, 6 A, 10 mA, MCB trip characteristic: D, 1p+N, RCD trip characteristic: A High-quality residual current device/miniature circuit breaker combination, line voltage-independent, contact position indicator red - green, terminal rear plug protection, tri-stable slide catch - enables removal from existing busbar system, comprehensive range of accessories suitable for subsequent installation, wide range of rated fault currents, rated operational currents up to 40 A, tripping characteristics B, C, D, rated breaking capacity 10 kA, suitable for outdoor use (on-site power and outdoor distribution board) up to -25 °C

Automation > Earth leakage circuit breaker
Modular Switchgear – Tertiary and Differential

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

RCD/MCB combination, 6 A, 10 mA, MCB trip characteristic: D, 1p+N, RCD trip characteristic: A
High-quality residual current device/miniature circuit breaker combination, line voltage-independent, contact position indicator red - green, terminal rear plug protection, tri-stable slide catch - enables removal from existing busbar system, comprehensive range of accessories suitable for subsequent installation, wide range of rated fault currents, rated operational currents up to 40 A, tripping characteristics B, C, D, rated breaking capacity 10 kA, suitable for outdoor use (on-site power and outdoor distribution board) up to -25 °C

Delivery program

Basic function
Combined RCD/MCB devices
Number of poles
1 pole+N
Tripping characteristic
D
Application
Switchgear for industrial and advanced commercial applications
Rated current [In]
6 A
Rated switching capacity according to IEC/EN 61009
10 kA
Rated fault current [IΔN]
0.01 A
Type
Type A
Tripping
non-delayed s…
Product range
FRBmM
Sensitivity
Pulse-current sensitive
Impulse withstand current
Partly surge-proof 250 A
Contact sequence
FL7

Technical data

Electrical
Protected pole
1
Rated voltage according to IEC/EN 60947-2 [Un]
240 V AC
Rated frequency [f]
50 Hz
Rated fault current [IΔn]
10 mA
Sensitivity
Pulse-current sensitive
Rated current [In]
6 A
Tripping characteristic
D

Design verification as per IEC/EN 61439

Heat dissipation per pole, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+40 °C

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Earth leakage circuit breaker (EC000905)
Electric engineering, automation, process control engineering / Electrical installation, device / Residual current protection system / MCB/RCCB combination ([email protected] [AFZ810015])
Number of poles (total)
2
Number of protected poles
1
Rated voltage
240 V
Rated insulation voltage Ui
500 V
Rated impulse withstand voltage Uimp
4 kV
Rated current
6 A
Rated fault current
0.01 A
Leakage current type
A
Current limiting class
3
Rated short-circuit breaking capacity acc. EN 61009
10 kA
Rated short-circuit breaking capacity IEC 60947-2
15 kA
Rated short-circuit breaking capacity Icn acc. EN 61009-1
10 kA
Disconnection characteristic
Surge current capacity
0.25 kA
Voltage type
AC
Frequency
50 Hz
Release characteristic
D
Concurrently switching N-neutral
Yes
With interlocking device
No
Over voltage category
3
Pollution degree
2
Ambient temperature during operating
-25 - 40 °C
Width in number of modular spacings
2
Built-in depth
75.5 mm
Suitable for flush-mounted installation
No
Anti-nuisance tripping version
No
Degree of protection (IP)
IP20
Connectable conductor cross section solid-core
1 - 25 mm²
Connectable conductor cross section multi-wired
1 - 25 mm²

Dimensions

Mas_FRBmM_1N_Kiska

ETIM for 170916 Circuit breakers and fuses (EC000905)
Feature Name Feature Value
Number of poles (total) (EF008618) 2
Number of protected poles (EF005548) 1
Rated voltage (EF000228) 240 V
Rated insulation voltage Ui (EF001366) 500 V
Rated impulse withstand voltage Uimp (EF011980) 4 kV
Rated current (EF000227) 6 A
Rated fault current (EF002358) 0.01 A
Leakage current type (EF002560) A
Current limiting class (EF002568) 3
Rated short-circuit breaking capacity according to EN 61009 (EF012628) 10 kA
Rated short-circuit breaking capacity according to IEC 60947-2 (EF006065) 15 kA
Rated short-circuit breaking capacity Icn according to EN 61009-1 (EF011981) 10 kA
Disconnection characteristic (EF012587) Undelayed
Surge current capacity (EF002564) 0.25 kA
Voltage type (EF000187) AC
Frequency (EF005455) 50 Hz
Release characteristic (EF000889) D
Concurrently switching neutral conductor (EF005997) Yes
With interlocking device (EF007385) No
Over voltage category (EF002569) 3
Pollution degree (EF002570) 2
Ambient temperature during operating (EF007515) -25 °C
Width in number of modular spacings (EF002950) 2
Built-in depth (EF000218) 75.5 mm
Anti-nuisance tripping version (EF009497) No
Degree of protection (IP) (EF005474) IP20
Connectable conductor cross section solid-core (EF007337) 1 mm²
Connectable conductor cross section multi-wired (EF007343) 1 mm²

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.