EATON - MOELLER FRBMM-B6/1N/003-A-RT FRBMM-B6/1N/003-A-RT 305114 Y7-305114 EATON ELECTRIC Combined Int. FRBMM, 6A, 30mA, B-Curve, 1P+N, Class A R.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

FRBMM-B6/1N/003-A-RT 305114 Y7-305114 EATON ELECTRIC Combined Int. FRBMM, 6A, 30mA, B-Curve, 1P+N, Class A R..

FRBMM-B6/1N/003-A-RT

305114

Y7-305114

EATON - MOELLER

1 Pcs.

Combined Int. FRBMM, 6A, 30mA, B-Curve, 1P+N, Class A Ring Terminal FRBMM-B6/1N/003-A-RT. RCD/MCB, 6A, 30mA, miniature circuit-breaker trip curve: B, 1pole+N, residual current circuit-breaker trip characteristic: A

Automation > Earth leakage circuit breaker
Modular Switchgear – Tertiary and Differential

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Moeller series xEffect - FRBm6/M RCBO - residual-current circuit breaker with overcurrent protection
Catalog Number
305114
Model Code
FRBMM-B6/1N/003-A-RT
EAN
9010238988552
Product Length/Depth
75.5 mm
Product Height
84.5 mm
Product Width
35.4 mm
Product Weight
0.199 kg
Compliances
RoHS conform
Certifications
EN45545-2
IEC 61373

Product specifications

Amperage Rating
10 A
Surge current capacity
0.25 kA
Voltage type
AC
Width in number of modular spacings
2
Operating ambient temperature - max
40 °C
Operating ambient temperature - min
-25 °C
Rated current
6 A
Rated switching capacity (IEC/EN 60947-2)
15 kA
Built-in depth
75.5 mm
Current limiting class
3
Rated short-circuit breaking capacity (EN 60947-2)
15 kA
Ambient operating temperature - max
40 °C
Ambient operating temperature - min
-25 °C
Fault current rating
0.03 A
Number of poles (protected)
1
Number of poles (total)
2
Rated operational voltage (Ue) - max
240 V
Rated short-circuit breaking capacity (IEC 60947-2)
15 kA
Rated impulse withstand voltage (Uimp)
4 kV
Degree of protection
IP20
Overvoltage category
III
Pollution degree
2
Leakage current type
A
Release characteristic
B
Frequency rating
50 Hz
Rated insulation voltage (Ui)
500 V
Connectable conductor cross section (solid-core) - min
1 mm²
Connectable conductor cross section (solid-core) - max
25 mm²
Connectable conductor cross section (multi-wired) - min
1 mm²
Connectable conductor cross section (multi-wired) - max
25 mm²
Rated short-circuit breaking capacity (EN 61009)
10 kA
Rated short-circuit breaking capacity (EN 61009-1)
10 kA
Disconnection characteristic
Undelayed

ETIM for 305114 Circuit breakers and fuses (EC000905)
Feature Name Feature Value
Number of poles (total) (EF008618) 2
Number of protected poles (EF005548) 1
Rated voltage (EF000228) 240 V
Rated insulation voltage Ui (EF001366) 500 V
Rated impulse withstand voltage Uimp (EF011980) 4 kV
Rated current (EF000227) 6 A
Rated fault current (EF002358) 0.03 A
Leakage current type (EF002560) A
Current limiting class (EF002568) 3
Rated short-circuit breaking capacity according to EN 61009 (EF012628) 10 kA
Rated short-circuit breaking capacity according to IEC 60947-2 (EF006065) 15 kA
Rated short-circuit breaking capacity Icn according to EN 61009-1 (EF011981) 10 kA
Disconnection characteristic (EF012587) Undelayed
Surge current capacity (EF002564) 0.25 kA
Voltage type (EF000187) AC
Frequency (EF005455) 50 Hz
Release characteristic (EF000889) B
Concurrently switching neutral conductor (EF005997) No
With interlocking device (EF007385) No
Over voltage category (EF002569) 3
Pollution degree (EF002570) 2
Ambient temperature during operating (EF007515) -25 °C
Width in number of modular spacings (EF002950) 2
Built-in depth (EF000218) 75.5 mm
Anti-nuisance tripping version (EF009497) No
Degree of protection (IP) (EF005474) IP20
Connectable conductor cross section solid-core (EF007337) 1 mm²
Connectable conductor cross section multi-wired (EF007343) 1 mm²

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.