EATON - MOELLER BP-F-1200/20/2,5 BP-F-1200/20/2,5 119191 EATON ELECTRIC Floor standing distribution board with three-point turn-lock, W 1200 .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

BP-F-1200/20/2,5 119191 EATON ELECTRIC Floor standing distribution board with three-point turn-lock, W 1200 ..

BP-F-1200/20/2,5

119191

EATON - MOELLER

1 Pcs.

Floor standing distribution board with three-point turn-lock, W = 1200 mm, H = 2060 mm, D = 250 mm Floor standing distribution board with cam lock, IP30, gray, RAL 7035, width 1200 mm, outside height 2060 mm, front plate height 1950 mm, depth 250 mm, includes top and bottom gland plate inserts, metal door with cam lock, door can be right-hand or left-hand door, mounting frame (on the back) without mounting rails, suitable only for MSW assembly configuration (no BPZ-CTS-S corner towers required), earthed metal covers, extraordinary stability as a result of welded construction, ample wiring area, variable interior fittings with / without removable mounting frame, well-structured , multilayered design for easily accessible installation: base frame - DIN-rails ... - enclosure

Automation > Enclosure/switchgear cabinet (empty)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Feed-in terminals 2,5-16qmm for PXS24-BB
Accessories for the 24V PXS24 fuse; supply terminal directly to the bus bar, 2.5 -16mm2, max. 60A
[

Delivery program

Basic function
Automation engineering 24V
Number of channels
0
Protection
none
Rated current [In]
60 A
Rated operating voltage [Un]
24 V
,

Technical data

Electrical
Operational voltage [UB]
24 DC (16 .. 30V DC)
Mechanical
Mounting
can be snapped onto PXS24 modules
Ambient temperature
-10 - +55 °C
Permissible storage and transport temperatures
-40 - +100 °C
,

Design verification as per IEC/EN 61439

IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
,

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Busbar terminal (EC000001)
Electric engineering, automation, process control engineering / Electrical installation, device / Terminal (not overhead line) / Switch board ([email protected] [BAA025013])
Busbar thickness
0 - 0 mm
Busbar width
0 - 0 mm
Suitable for
T-rail
Width clamp
7 mm
Max. conductor cross section
16 mm²
Max. rated operation current Ie
60 A
Suitable for round conductor connection
Yes
Suitable for sector conductor connection
No
Suitable for strip conductor connection
No
]

ETIM for 119191 Cabinets and enclosures (EC000261)
Feature Name Feature Value
Width (EF000008) 1215 mm
Height (EF000040) 2080 mm
Depth (EF000049) 265 mm
Material (EF002169) Steel
Material quality (EF001257) Other
Surface finishing (EF006569) Powder coated
Colour (EF000007) Grey
RAL-number (EF000116) 7035
Freestanding (EF020363) Yes
Floor standing wall model (EF015208) No
Suitable for wall mounting (EF000664) No
Corner model (EF020814) No
Intermediate mounting (EF022994) No
Couplable (EF001229) No
With mounting plate (EF000118) No
Mounting plate depth-adjustable (EF006054) Yes
Suitable for wall built-in (EF007536) No
Pole fastening (EF009582) No
With door (EF009169) Yes
Number of doors (EF000122) 2
With glazed door (EF001089) No
With ventilation door (EF006279) No
With rear door (EF007381) No
Number of locks (EF000123) 1
With cover (EF007965) No
Transparent cover (EF011401) No
Suitable for metrical mounting (EF005823) Yes
Pitched roof (EF009278) No
Number of connector holes (EF005554) 0
Pre-stamping (EF001039) No
EMC-version (EF001062) Yes
Impact strength (EF004293) IK08
Degree of protection (IP) (EF005474) IP30
Degree of protection (NEMA) (EF011959) Other
Thermal dissipation (Delta T = 20 K) according to IEC/TR 60890 (EF014986) 0 W
Max. permissible load of the enclosure according to IEC 62208 (EF014987) 0 N
Max. permissible load of the door(s) according to IEC 62208 (EF014988) 0 N
Max. permissible load of the mounting plate according to IEC 62208 (EF014989) 0 N

Product Datasheet