ZB4-101-GF1 061360 EATON ELECTRIC PS compact controllers
ZB4-101-GF1
061360
EATON - MOELLER
9 Pcs.
PS compact controllers
Device feet for mounting for easyRelay, easyE4, EC4P, ES4P, MFD-CP8/CP10 und XC-152
Automation > Accessories/spare parts for controls
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller PS compact controllers (ZB4-101-GF1) function as modular processing units designed to manage localized automation tasks, logic operations, and machine control sequences.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Accessory (EF013236): Yes
- Spare part (EF013237): No
More info
▲Fixing bracket, for easy500, 700, 800, EC4P, ES4P, easy200, MFD-CP8/CP10
Device feet for mounting for easy500, easy700, easy800, EC4P, ES4P, easy200, MFD-CP8/CP10
Delivery program
Product range
Control relay easyRelay
Multi-function-display MFD-Titan
Control relays easyE4
XC-152 Compact PLC
EC4P compact PLCs
Multi-function-display MFD-Titan
Control relays easyE4
XC-152 Compact PLC
EC4P compact PLCs
Accessories
Mounting accessories
Accessories
Mounting foot
Function
For screw fixing to mounting plate
Description
3 Device feet per easy400, 500, 600, 700, 800, EC4P, ES4P, MFD-CP8/CP10
3 Device feet per easyE4 basic device and easyE4 extensions, easy-E4- ...-16.E..
2 fixing bracket per easy200
2 Device feet per easyE4 extensions easy-E4-...-8.E..., easy-E4-...-6.E..., easy-E4-...-4.E..
4 fixing brackets per XC-152
3 Device feet per easyE4 basic device and easyE4 extensions, easy-E4- ...-16.E..
2 fixing bracket per easy200
2 Device feet per easyE4 extensions easy-E4-...-8.E..., easy-E4-...-6.E..., easy-E4-...-4.E..
4 fixing brackets per XC-152
For use with
ZEV
ZEV-XSW-25
ZEV-XSW-65
ZEV-XSW-145
easy…, MFD…
PS4…, EM4…
LE4…
XC152
easyE4
ZEV-XSW-25
ZEV-XSW-65
ZEV-XSW-145
easy…, MFD…
PS4…, EM4…
LE4…
XC152
easyE4
Design verification as per IEC/EN 61439
Technical data for design verification
Rated operational current for specified heat dissipation [In]
0 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+55 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 7.0
PLC's (EG000024) / Accessories for controls (EC002584)
Electric engineering, automation, process control engineering / Control / Programmable logic control (SPS) / Programmable logic control (SPS, accessories) ([email protected] [AFR333003])
Type of electrical accessory
Other
Type of mechanical accessory
Other
Approvals
North America Certification
UL/CSA certification not required