Used with
Diagnostics, communication
Accessories required
Separate external bus termination
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Isolation
Between bus and power supply (simple), between bus and power supply and NZM-XDMI612 (safe potential isolation)
Accessory/spare part type
Diagnostics and communication
Display
Profibus-DP LED (BUS): red
Explosion safety category for dust
Explosion safety category for gas
Mounting method
Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Front build in possible
Rail mounting possible
Acyclic network services
Display/match protection settings, event list, identification, hours of operation, switching operations, time
Safety performance level (EN ISO 13849-1)
Vibrations at constant acceleration 2 g (IEC/EN 60068-2-6)
Vibrations at constant amplitude .15 mm (IEC/EN 61131-2:2008)
Ambient operating temperature - min
Ambient storage temperature - max
Ambient storage temperature - min
Drop height (IEC/EN 60068-2-31)
EMC of electromagnetic fields rfi (IEC EN 61000-4-3)
EMC of electrostatic air discharge level 3 (IEC/EN 61000-4-2)
Heat dissipation of power supply at 24 V DC
EMC of electrostatic contact discharge level 3 (IEC/EN 61000-4-2)
Power supply admissable - max
Terminal capacity (cable)
0.2 mm² - 2.5 mm² with ferrule
AWG 22 - AWG 12 with ferrule
Terminal capacity (solid wire)
0.2 mm² - 4 mm² (AWG 22 - AWG 12)
Functions
Protection against polarity reversal, AS-I power supply
PROFIBUS-DP slave
Corrosion resistance
1 cm³/m³ (4 days SO₂)
10 cm³/m³ (4 days SO₂)
Shock resistance
18 impacts (IEC 60068-2-27)
Operating air pressure - max
Operating air pressure - min
Packaged free fall height (IEC/EN 60068-2-32)
Power supply admissable - min
Power supply status display
Supply voltage at AC, 50 Hz - max
Supply voltage at AC, 50 Hz - min
Supply voltage at AC, 60 Hz - max
Supply voltage at AC, 60 Hz - min
Supply voltage at DC - max
Supply voltage at DC - min
Rated current of power supply
Services (cyclic)
Remote operator actuation, display/operation NZM-XDMI612 inputs/outputs, motor starter functions
Status ON/OFF/tripped (detailed), load early warnings, phase currents I1/I2/I3 [A]
EMC of power pulses/surge level 2 (IEC/EN 61000-4-5)
0.5 kV (supply cables, symmetrical)