Residual current circuit breaker (RCCB), 25A, 2p, 30mA, type A Residual current circuit-breaker, 25A, 2p, 03A, A-Char Residual current circuit-breaker FI, 2 pole, Rated current In: 25 A, Rated short-circuit strength Icn: 10 kA, Rated fault current IΔN: 0.03 A

Automation > Residual current circuit breaker (RCCB)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Residual current circuit-breaker, 25A, 2p, 03A, A-Char
Residual current circuit-breaker FI, 2 pole, Rated current In: 25 A, Rated short-circuit strength Icn: 10 kA, Rated fault current IΔN: 0.03 A

Delivery program

Basic function
Residual current circuit-breakers
Number of poles
2 pole
Rated current [In]
25 A
Rated short-circuit strength [Icn]
10 kA
Rated fault current [IΔN]
0.03 A
Type
Type A
Tripping
non-delayed s…
Product range
FI
Sensitivity
AC and pulsating DC current sensitive
Impulse withstand current
Partly surge-proof 250 A

Technical data

Electrical
Standards
IEC/EN 61008
Tripping
non-delayed s…
Rated operating voltage [Ue]
230/400 V AC
Limit values of the operating voltage
184 … 440 V AC
Rated frequency [f]
50 Hz
Rated fault currents [IΔn]
30, 100, 300, 500 mA
Rated non-tripping current [IΔno]
0.5 x I∆n
Rated fault switching capacityRated fault switching capacity [IΔm]
In = 16…40 A: 500
In = 63 A: 630
In = 80 A: 800
In = 100A: 1000 A
Sensitivity
DC and pulsed current
Rated switching capacity [Icn]
10 kA
Rated current [Ie]
25 A
Rated impulse withstand voltage [Uimp]
6 kV
Maximum max. as short-circuit protective device
In = 16 - 63 A: 63
In= 80 A: 80
In= 100 A: 100 A gL
LifespanElectrical
> 4000 Operations
LifespanMechanical
> 20000 Operations
Mechanical
Standard front dimension
45 mm
Enclosure height
80 mm
Terminal protection
Protection against electric shock to IEC 536
Mounting width
35 (2 space unit), 70 (4 space units) mm
Mounting
Top-hat rail IEC/EN 60715
Degree of protectionIntegrated
IP40
Terminals top and bottom
Twin-purpose terminals
Terminal capacitiesSolid
1.5 … 35 mm2
Terminal capacitiesflexible
2 x 16 mm2
Thickness of busbar material
0.8 … 2 mm
Admissible ambient temperature range
-25 … +40 °C
Climatic proofing
IEC/EN 61008

Design verification as per IEC/EN 61439

Rated operational current for specified heat dissipation [In]
25 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
2 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+55 °C
Starting at 40 °C, the max. permissible continuous current decreases by 3% for every 1 °C

Technical data ETIM 7.0

Circuit breakers and fuses (EG000020) / Residual current circuit breaker (RCCB) (EC000003)
Electric engineering, automation, process control engineering / Electrical installation, device / Residual current protection system / Residual current circuit breaker (RCCB) ([email protected] [AAB906014])
Number of poles
2
Rated voltage
230 V
Rated current
25 A
Rated fault current
30 mA
Rated insulation voltage Ui
V
Rated impulse withstand voltage Uimp
kV
Mounting method
DIN rail
Leakage current type
A
Selective protection
No
Short-time delayed tripping
No
Short-circuit breaking capacity (Icw)
10 kA
Surge current capacity
0.25 kA
Frequency
50 Hz
Additional equipment possible
Yes
With interlocking device
Degree of protection (IP)
IP20
Width in number of modular spacings
2
Built-in depth
69.5 mm
Ambient temperature during operating
-25 - 40 °C
Pollution degree
2
Connectable conductor cross section multi-wired
mm²
Connectable conductor cross section solid-core
mm²

Dimensions

122X023

ETIM for 279184 Circuit breakers and fuses (EC000003)
Feature Name Feature Value
Number of poles (EF001391) 2
Rated voltage (EF000228) 230 V
Rated current (EF000227) 25 A
Rated fault current (EF002358) 0.03 A
Mounting method (EF000003) DIN rail
Leakage current type (EF002560) A
Selective protection (EF002561) No
Short-time delayed tripping (EF003604) No
Short-circuit breaking capacity (Icw) (EF002562) 10 kA
Surge current capacity (EF002564) 0.25 kA
With interlocking device (EF007385) No
Frequency (EF005455) 50 Hz
Additional equipment possible (EF008148) Yes
Degree of protection (IP) (EF005474) IP40
Width in number of modular spacings (EF002950) 2
Built-in depth (EF000218) 69.5 mm
Ambient temperature during operating (EF007515) -25 °C
Pollution degree (EF002570) 2
Explosion-proof (EF004663) No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.