EATON - MOELLER EU5C-SWD-PF2-1 EU5C-SWD-PF2-1 116380 Y7-116380 EATON ELECTRIC Feeder module, SmartWire-DT, supply for contactors and SWD mo.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

EU5C-SWD-PF2-1 116380 Y7-116380 EATON ELECTRIC Feeder module, SmartWire-DT, supply for contactors and SWD mo..

EU5C-SWD-PF2-1

116380

Y7-116380

EATON - MOELLER

1 Pcs.

Feeder module, SmartWire-DT, supply for contactors and SWD modules EU5C-SWD-PF2-1 Eaton EU5C SWD power supply for SWD modules and contactors SmartWire-DT power supply for SWD modules and for additionally feeding the control voltage for motor starters and contactors, as well as for establishing emergency stop groups

Automation > Fieldbus, decentr. periphery - power supply/segment module
Smartwire Darwin

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton EU5C Accessory Power supply
Catalog Number
116380
Model Code
EU5C-SWD-PF2-1
EAN
4015081161102
Product Length/Depth
125 mm
Product Height
90 mm
Product Width
35 mm
Product Weight
0.16 kg
Certifications
UL Category Control No.: NKCR
CSA
CSA Class No.: 3211-07
IEC/EN 61131-2
UL File No.: E29184
EN 50178
UL
CSA File No.: 2324643
Catalog Notes
SmartWire-DT power supply for SmartWire-DT modules and for additionally feeding the control voltage for motor starters and contactors, as well as for establishing emergency stop groups

Features & Functions

Electric connection type
Flat plug-in connection
Features
Fieldbus connection over separate bus coupler possible
Overload proof
Fitted with:
Power supply module
Potential separation
Functions
For additional control voltage feeder for the motor starter and contactors
For the formation of emergency switching off groups for motor starters and contactors
For feeding supply voltage in order to connect additional SmartWire-DT modules to the SmartWire-DT ribbon cable

General

Degree of protection
IP20
Mounting method
Rail mounting possible
Wall mounting/direct mounting
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Overvoltage category
II
Pollution degree
2
Product category
SmartWire-DT accessories
Repetition rate
1 s
Residual ripple
≤ 5 % (input voltage)
Suitable as
Segment module
Terminal capacity
0.25 - 1.5 mm², flexible with ferrule
24 - 16 AWG, solid or stranded
0.2 - 1.5 mm², solid
Voltage type
DC

Ambient conditions, mechanical

Constant acceleration
1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
Constant amplitude
3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
Drop and topple
50 mm Drop height, Drop to IEC/EN 60068-2-31
Height of fall (IEC/EN 60068-2-32) - max
0.3 m
Mounting position
As required
Shock resistance
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts

Climatic environmental conditions

Air pressure
795 - 1080 hPa (operation)
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
55 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
70 °C
Climatic proofing
Damp heat, constant, to IEC 60068-2-3
Dry heat to IEC 60068-2-2
Environmental conditions
Condensation: prevent with appropriate measures
Operating temperature - min
-25 °C
Operating temperature - max
55 °C
Relative humidity
5 - 95 % (non-condensing, IEC/EN 60068-2-30)

Electro magnetic compatibility

Air discharge
8 kV, according to IEC 61131-2, level 3, ESD
Burst impulse
2 kV, Supply cable, according to IEC/EN 61131-2, Level 3
1 kV, SmartWire-DT cable, according to IEC/EN 61131-2, Level 3
Contact discharge
4 kV, according to IEC/EN 61131-2, Level 2, ESD
Electromagnetic fields
3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008)
1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008)
10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008)
Radiated RFI
10 V (IEC/EN 61131-2:2008, Level 3)
Radio interference class
Class A (EN 55011)
Surge rating
0.5 kV, Supply cables/CAN/DP bus cable, Surge power cables, Surge (IEC/EN 61131-2:2008, Level 1), EMC
Voltage dips
≤ 10 ms, Bridging voltage dips

Electrical rating

Inrush current
12.5 A (for 6 ms)
Power loss
Normally 2.7 W
Rated control supply voltage
24 V DC (UPOW, -15 %/+20 %)
24 V DC (UAUX, -15 %/+20 %)
Rated operational current (Ie) - max
0.7 A
Rated operational voltage
Typically UAUX -0.2 V (for 24 V DC slaves)
14.5 V (± 3 % - SmartWire-DT)
Short-circuit protection
Yes, Short-circuit rating, SmartWire-DT supply voltage
No, external fuse FAZ Z3, Supply voltage UAux
Supply current
0.7 A, Imax, SmartWire-DT supply
3 A, Imax, Supply voltage UAux
Supply voltage at AC, 50 Hz - min
0 VAC
Supply voltage at AC, 50 Hz - max
0 VAC
Supply voltage at DC - min
20.4 VDC
Supply voltage at DC - max
28.8 VDC

Communication

Connection
2 x SmartWire-DT blade terminal SWD4-8MF2
Connection to SmartWire-DT
Yes
Connection type
SWD: 2 x plug, 8-pole
Push in terminals, Supply voltage
LED indicator
Status indication of Supply voltage: LED
Protocol
Other bus systems

Safety

Explosion safety category for dust
None
Explosion safety category for gas
None
Potential isolation
Between UPow and 15 V SmartWire-DT supply voltage: yes
Protection against polarity reversal
Yes
Yes, for supply voltage (Siemens MPI optional)

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
2.7 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 116380 PLC's (EC001600)
Feature Name Feature Value
Supply voltage AC 50 Hz (EF007532) 0 V
Supply voltage AC 60 Hz (EF007533) 0 V
Supply voltage DC (EF007534) 20.4 V
Voltage type (supply voltage) (EF002991) DC
Number of HW-interfaces industrial Ethernet (EF003020) 0
Number of interfaces PROFINET (EF006932) 0
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 0
Number of HW-interfaces serial TTY (EF003024) 0
Number of HW-interfaces parallel (EF003026) 0
Number of HW-interfaces wireless (EF006933) 0
Number of HW-interfaces USB (EF003025) 0
Number of HW-interfaces other (EF003027) 1
With optical interface (EF003028) false
Supporting protocol for EtherCAT (EF017564) false
Supporting protocol for TCP/IP (EF003050) false
Supporting protocol for PROFIBUS (EF003052) false
Supporting protocol for CAN (EF003053) false
Supporting protocol for INTERBUS (EF003054) false
Supporting protocol for ASI (EF003051) false
Supporting protocol for KNX (EF003055) false
Supporting protocol for Modbus (EF003057) false
Supporting protocol for Data-Highway (EF003058) false
Supporting protocol for DeviceNet (EF003059) false
Supporting protocol for SUCONET (EF003060) false
Supporting protocol for LON (EF003017) false
Supporting protocol for PROFINET IO (EF007525) false
Supporting protocol for PROFINET CBA (EF007524) false
Supporting protocol for SERCOS (EF006657) false
Supporting protocol for Foundation Fieldbus (EF007522) false
Supporting protocol for EtherNet/IP (EF007521) false
Supporting protocol for AS-Interface Safety at Work (EF007519) false
Supporting protocol for DeviceNet Safety (EF007520) false
Supporting protocol for INTERBUS-Safety (EF006662) false
Supporting protocol for PROFIsafe (EF007526) false
Supporting protocol for SafetyBUS p (EF007527) false
Supporting protocol for other bus systems (EF003062) true
Radio standard Bluetooth (EF007178) false
Radio standard WLAN 802.11 (EF007179) false
Radio standard GPRS (EF008523) false
Radio standard GSM (EF008524) false
Radio standard UMTS (EF008525) false
System accessory (EF004118) true
Degree of protection (IP) (EF005474) IP20
Type of electric connection (EF003961) Flat plug-in connection
With potential separation (EF003272) true
With power supply module (EF003993) true
Suitable as segment module (EF004104) true
Remote module (EF006653) false
Fieldbus connection over separate bus coupler possible (EF004002) true
Bus diagnosis possible (EF003989) false
Suitable for rail mounting (EF003972) true
Wall mounting/direct mounting (EF007020) true
Front built-in possible (EF007016) false
Rack-assembly possible (EF007018) false
Suitable for safety functions (EF001597) false
SIL according to IEC 61508 (EF009889) None
Performance level according to EN ISO 13849-1 (EF007399) None
Appendant operation agent (Ex ia) (EF004141) false
Appendant operation agent (Ex ib) (EF004142) false
Explosion safety category for gas (EF003997) None
Explosion safety category for dust (EF003998) None
Certified for UL hazardous location class I (EF017622) false
Certified for UL hazardous location class II (EF017625) false
Certified for UL hazardous location class III (EF017627) false
Certified for UL hazardous location division 1 (EF017628) false
Certified for UL hazardous location division 2 (EF017629) false
Certified for UL hazardous location group A (acetylene) (EF017632) false
Certified for UL hazardous location group B (hydrogen) (EF017633) false
Certified for UL hazardous location group C (ethylene) (EF017635) false
Certified for UL hazardous location group D (propane) (EF017636) false
Certified for UL hazardous location group E (metal dusts) (EF017637) false
Certified for UL hazardous location group F (carbonaceous dusts) (EF017638) false
Certified for UL hazardous location group G (non-conductive dusts) (EF017639) false
Width (EF000008) 35 mm
Height (EF000040) 90 mm
Depth (EF000049) 125 mm

Product Datasheet