View larger
FAZ6-B13/3 239112 Y7-239112 EATON ELECTRIC Int. Magentothermal FAZ6, 3 P, 13 A, B-curve, 6/10kA
FAZ6-B13/3
239112
Y7-239112
EATON - MOELLER
1 Pcs.
Automation > Miniature circuit breaker (MCB)
Modular Switchgear - Tertiary
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller part number FAZ6-B13/3 239112 is a magentothermal circuit breaker from the xEffect series, engineered to interrupt overloads and short circuits in three-pole configurations. These reliable switching devices are standard in industrial control panels and commercial building electrical systems.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Name: Eaton Moeller series xEffect - FAZ6 MCB
- Catalog Number: 239112
- Model Code: FAZ6-B13/3
- EAN: 4015082391126
- Product Length/Depth: 85 mm
- Product Height: 73 mm
- Product Width: 53.1 mm
- Product Weight: 0.36 kg
- Compliances: RoHS conform
- Certifications: CE
- Number of poles (total): 3
- Number of poles (protected): 3
- Release characteristic: B
- Amperage Rating: 13 A
- Voltage type: AC
- Voltage rating (IEC/EN 60898-1): 415 V
More info
▲General specifications
| Product Name | Eaton Moeller series xEffect - FAZ6 MCB |
| Catalog Number | 239112 |
| Model Code | FAZ6-B13/3 |
| EAN | 4015082391126 |
| Product Length/Depth | 85 mm |
| Product Height | 73 mm |
| Product Width | 53.1 mm |
| Product Weight | 0.36 kg |
| Compliances | RoHS conform |
| Certifications | CE |
Delivery program
| Number of poles (total) | 3 |
| Number of poles (protected) | 3 |
| Release characteristic | B |
| Amperage Rating | 13 A |
Technical Data - Electrical
| Voltage type | AC |
| Voltage rating (IEC/EN 60898-1) | 415 V |
| Voltage rating (IEC/EN 60947-2) | 400 |
| Rated operational voltage (Ue) - max | 230 V |
| Operational voltage (IEC/EN 60947-2) - max | 400 V |
| Operational voltage at DC (EC/EN 60947-2) - max | 60 V |
| Rated insulation voltage (Ui) | 440 V |
| Rated impulse withstand voltage (Uimp) | 4 kV |
| Frequency rating - min | 50 Hz |
| Frequency rating - max | 60 Hz |
| Rated switching capacity (IEC/EN 60947-2) | 7.5 kA |
| Overvoltage category | III |
| Pollution degree | 2 |
Technical Data - Mechanical
| Width in number of modular spacings | 3 |
| Built-in depth | 70.5 mm |
| Connectable conductor cross section (solid-core) - min | 1 mm² |
| Connectable conductor cross section (solid-core) - max | 25 mm² |
| Connectable conductor cross section (multi-wired) - min | 1 mm² |
| Connectable conductor cross section (multi-wired) - max | 25 mm² |
Design verification as per IEC/EN 61439 - technical data
| Rated operational current for specified heat dissipation (In) | 13 A |
| Equipment heat dissipation, current-dependent | 7.8 W |
| Ambient operating temperature - min | -25 °C |
| Ambient operating temperature - max | 75 °C |
Design verification as per IEC/EN 61439
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Additional information
| Current limiting class | 3 |
| Features | Additional equipment possible |