EATON - MOELLER FAZ-XAA-NA12-110VAC FAZ-XAA-NA12-110VAC 102037 Y7-102037 EATON ELECTRIC Coil shooting, up to 40 A, 12-110V View larger
Images are for illustrative purposes only. Please refer to data sheet for details

FAZ-XAA-NA12-110VAC 102037 Y7-102037 EATON ELECTRIC Coil shooting, up to 40 A, 12-110V

FAZ-XAA-NA12-110VAC

102037

Y7-102037

EATON - MOELLER

1 Pcs.

Coil shooting, up to 40 A, 12-110V FAZ-XAA-NA12-110VAC Eaton Distribution parts. Shunt release, up to 63A, 12-110V Shunt release, for MCB up to 63A, voltage range 12-110V AC / 12-60V DC, standard front dimension 45 mm, mounting width 1 SU (17.5mm), top-hat rail mounting, terminal cross-section AWG 18-10

Automation > Auxiliary device for distribution board devices
Modular Switchgear – Others and Accessories

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Distribution parts
Catalog Number
102037
Model Code
FAZ-XAA-NA12-110VAC
EAN
4015081019281
Product Length/Depth
105 mm
Product Height
75.5 mm
Product Width
17.7 mm
Product Weight
0.11 kg
Compliances
RoHS conform
Certifications
CSA (Class No. 1437-01)
North America (UL listed, CSA certified)
UL (Category Control Number DIHS, DIHS7)
CSA-C22.2 No. 5-09
IEC/EN 60898
UL (File No. E257181)
CE marking
UL 489
CSA (File No. 204453)
EN45545-2
IEC 61373

Product specifications

Type
Application
Switchgear for 110-V systems
Accessory/spare part type
Shunt release
Degree of protection
UL/CSA Type: -
IP20 (IEC)
IP40
Frame
Standard front dimension: 45 mm
Frequency rating
50 Hz / 60 Hz
Used with
Shunt releases
Accessory
Accessory for miniature circuit breaker
Mounting method
For fitting on left to: FAZ-NA, FAZ-RT
Quick attachment with 2 latch positions for top-hat rail EN 50022
Additional equipment required
Shunt release (for power circuit breaker)
Terminal protection
Busbar tag shroud to BGV A3
Terminal type
Twin-purpose terminals
Voltage range
12 V AC - 110 V AC
Ambient operating temperature - max
40 °C
Ambient operating temperature - min
-5 °C
Assembly width
1 TE
Enclosure width
105 mm
Number of contacts (change-over contacts)
0
Number of contacts (normally closed contacts)
1
Number of contacts (normally open contacts)
1
Number of poles at main contact unit - max
1
Number of switches (fault signal)
0
Voltage type
AC/DC
Functions
Shunt release (for power circuit breaker)
Device fitting
Miniature circuit breaker (MCB)
Mounting width
17.5 mm (1 space unit)
Rated operational voltage (Ue) - max
110 V
Rated switch current
0 A
Suitable for current of main contact unit - max
0 A

ETIM for 102037 Modular devices for distribution board/surface mounting (EC001286)
Feature Name Feature Value
Device fitting (EF007826) Miniature circuit breaker (MCB)
Function (EF000030) Shunt release (for power circuit breaker)
Width in number of modular spacings (EF002950) 1
Number of contacts as normally open contact (EF008256) 1
Number of contacts as normally closed contact (EF008255) 1
Number of contacts as change-over contact (EF008257) 0
Number of fault-signal switches (EF007613) 0
Rated switch current (EF006706) 0 A
Rated voltage (EF000228) 110 V
Voltage type (EF000187) AC/DC
With auto test for earth leakage function (EF008727) No
Suitable for max. number of poles main contact unit (total) (EF008729) 1
Suitable for max. current main contact unit (EF008730) 0 A

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.