EATON - MOELLER FAZ-PN-C6/1N FAZ-PN-C6/1N 279156 Y7-279156 EATON ELECTRIC Miniature circuit breaker (MCB), 6A, 1Np, C-Char, AC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

FAZ-PN-C6/1N 279156 Y7-279156 EATON ELECTRIC Miniature circuit breaker (MCB), 6A, 1Np, C-Char, AC

FAZ-PN-C6/1N

FAZ-PN-C6/1N

Y7-279156

EATON - MOELLER

1 unit

Miniature circuit breaker (MCB), 6A, 1Np, C-Char, AC FAZ-PN-C6/1N Eaton Moeller series xEffect - FAZ-PN MCB. FAZ-PN, 1-pole+N, tripping characteristic: C, rated current In: 6 A Miniature circuit breaker (MCB), FAZ-PN, 1-pole+N, tripping characteristic: C, rated current In: 6 A, Switchgear for industrial and advanced commercial applications

Automation > Miniature circuit breaker (MCB)
Modular Switchgear - Tertiary

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Moeller series xEffect - FAZ-PN MCB
Catalog Number
279156
Model Code
FAZ-PN-C6/1N
EAN
4015082791568
Product Length/Depth
80 mm
Product Height
75.5 mm
Product Width
17.5 mm
Product Weight
0.111 kg
Compliances
RoHS conform
Certifications
IEC/EN 60898
EN45545-2
IEC 61373

Product specifications

Type
Application
  • Switchgear for industrial and advanced commercial applications
  • xEffect - Switchgear for industrial and advanced commercial applications
Amperage Rating
6 A
Voltage rating
240 V AC / 415 V AC
Features
Concurrently switching N-neutral
Additional equipment possible
Frame
45 mm
Pollution degree
2
Used with
Miniature circuit breaker
FAZ-PN
Mounting Method
Top-hat rail IEC/EN 60715
Degree of protection
IP20
IP40 (when fitted)
Rated impulse withstand voltage (Uimp)
4 kV
Admissible back-up fuse - max
100 A gL/gG
Terminal protection
Finger and hand touch safe, DGUV VS3, EN 50274
Terminals (top and bottom)
Twin-purpose terminals
Tripping characteristic
C
Ambient operating temperature - max
75 °C
Ambient operating temperature - min
-25 °C
Built-in depth
70.5 mm
Connectable conductor cross section (multi-wired) - max
25 mm²
Connectable conductor cross section (multi-wired) - min
1 mm²
Connectable conductor cross section (solid-core) - max
25 mm²
Connectable conductor cross section (solid-core) - min
1 mm²
Current limiting class
3
Enclosure width
80 mm
Frequency rating - max
60 Hz
Frequency rating - min
50 Hz
Direction of incoming supply
As required
Width in number of modular spacings
1
Voltage rating at DC
60 V DC (per pole)
Voltage type
AC
Overvoltage category
III
Number of poles
Single-pole + N
Lifespan, electrical
4000 operations
Release characteristic
C
Mounting width
17.5 mm
Selectivity class
3
Mounting width per pole
17.5 mm
Number of poles (protected)
1
Number of poles (total)
2
Rated insulation voltage (Ui)
440 V
Rated operational voltage (Ue) - max
230 V
Rated short-circuit breaking capacity (EN 60898) at 230 V
6 kA
Rated short-circuit breaking capacity (EN 60898) at 400 V
6 kA
Rated short-circuit breaking capacity (IEC 60947-2) at 230 V
10 kA
Rated short-circuit breaking capacity (IEC 60947-2) at 400 V
10 kA
Rated switching capacity (IEC/EN 60947-2)
10 kA
Terminal capacity (control cable)
16 mm² (1x)
Power loss
1.1 W

ETIM for 279156 Circuit breakers and fuses (EC000042)
Feature Name Feature Value
Built-in depth (EF000218) 70.5 mm
Release characteristic (EF000889) C
Number of poles (total) (EF008618) 2
Number of protected poles (EF005548) 1
Rated current (EF000227) 6 A
Rated voltage (EF000228) 230 V
Rated insulation voltage Ui (EF001366) 440 V
Rated impulse withstand voltage Uimp (EF011980) 4 kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V (EF009556) 6 kA
Voltage type (EF000187) AC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V (EF009555) 6 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V (EF009557) 10 kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V (EF009558) 10 kA
Frequency (EF000416) 50 Hz
Power loss (EF005387) 1.1 W
Current limiting class (EF002568) 3
Flush-mounted installation (EF007517) No
Concurrently switching neutral conductor (EF005997) Yes
Over voltage category (EF002569) 3
Pollution degree (EF002570) 2
Additional equipment possible (EF008148) Yes
Width in number of modular spacings (EF002950) 1
Degree of protection (IP) (EF005474) IP20
Ambient temperature during operating (EF007515) -25 °C
Connectable conductor cross section multi-wired (EF007343) 1 mm²
Connectable conductor cross section solid-core (EF007337) 1 mm²
Explosion-proof (EF004663) No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.