View larger
FAZ-C8/4-NA 190925 Y7-190925 EATON ELECTRIC Miniature circuit breaker (MCB), C8, 4 poles, NA
FAZ-C8/4-NA
190925
Y7-190925
EATON - MOELLER
1 Pcs.
Automation > Miniature circuit breaker (MCB)
Modular Switchgear – Industrial
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
FAZ-C8/4-NA 190925 Y7-190925 EATON ELECTRIC Miniature circuit breaker (MCB), C8, 4 poles, NA is a miniature circuit breaker designed to automatically interrupt electrical circuits during overload or short-circuit conditions, protecting sensitive wiring and connected industrial equipment from damage. These protective devices are commonly installed in distribution boards and control panels to safeguard electrical infrastructure across commercial and manufacturing facilities.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Built-in depth (EF000218): 60 mm
- Release characteristic (EF000889): C
- Number of poles (total) (EF008618): 4
- Number of protected poles (EF005548): 4
- Rated current (EF000227): 8 A
- Rated voltage (EF000228): 240 V
- Rated insulation voltage Ui (EF001366): 440 V
- Rated impulse withstand voltage Uimp (EF011980): 4 kV
- Voltage type (EF000187): AC
- Frequency (EF000416): 50 Hz
- Power loss (EF005387): 5.2 W
- Current limiting class (EF002568): 3
- Flush-mounted installation (EF007517): Yes
- Concurrently switching neutral conductor (EF005997): No
- Over voltage category (EF002569): 3
- Pollution degree (EF002570): 2
More info
▲General specifications
UL 489, CSA C22.2 No. 5
IEC 60947-2
CE marking
UL 489
CSA (Class No. 1432-01)
CSA (File No. 204453)
UL (Category Control Number DIVQ)
UL (File No. E235139)
Specially designed for North America, suitable as BCPD
CSA-C22.2 No. 5-09
IEC/EN 60947-2
EN45545-2
IEC 61373
Delivery program
- FAZ-NA
- Miniature circuit breaker
Technical data - electrical
min. 6000 operations (UL)
Technical data - mechanical
IP20 (IEC)
UL/CSA Type: -
IP20
UL: 4 Nm (36 lb-in) for AWG 6
UL: 2.8 Nm (25 lb-in) for AWG 10 - AWG 8
Max. 2.4 Nm
Design verification as per IEC/EN - technical data
Design verification as per IEC/EN 61439
Additional information
- Ambient temperature hint: a 1 °C increase results in a 0.5% linear reduction of current carrying capacity
- Tripping signal contact for subsequent installation Z-NHK 248434
FAZ-NA
Miniature circuit breaker