View larger
FAZ-B50/2-RT
190799
Y7-190799
EATON - MOELLER
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Product Name | Eaton Moeller series xEffect - FAZ-NA, FAZ-RT MCB |
| Catalog Number | 190799 |
| Model Code | FAZ-B50/2-RT |
| EAN | 4015081904464 |
| Product Length/Depth | 105 mm |
| Product Height | 75.5 mm |
| Product Width | 35.4 mm |
| Product Weight | 0.259 kg |
| Compliances | RoHS conform |
| Certifications | CSA (Class No. 1432-01) CSA (File No. 204453) IEC/EN 60947-2 IEC 60947-2 UL 489 North America (UL listed, CSA certified) CE marking CSA-C22.2 No. 5-09 UL 489, CSA C22.2 No. 5 Specially designed for North America, suitable as BCPD UL (Category Control Number DIVQ) UL (File No. E235139) EN45545-2 IEC 61373 |
| Application |
|
| Number of poles | Two-pole |
| Number of poles (total) | 2 |
| Number of poles (protected) | 2 |
| Tripping characteristic | B |
| Release characteristic | B |
| Amperage Rating | 50 A |
| Type |
|
| Voltage type | AC |
| Voltage rating | 277 V AC / 480 V AC |
| Voltage rating at DC | 60 V DC |
| Voltage rating (IEC/EN 60947-2) | 415 V |
| Voltage rating (UL) | 240 V |
| Rated operational voltage (Ue) - max | 240 V |
| Rated insulation voltage (Ui) | 440 V |
| Rated impulse withstand voltage (Uimp) | 4 kV |
| Frequency rating - min | 50 Hz |
| Frequency rating - max | 60 Hz |
| Rated switching capacity (IEC/EN 60947-2) | 15 kA |
| Operational switching capacity | 7.5 kA |
| Breaking capacity | 10 kA (UL489) |
| Admissible back-up fuse - max | 125 A gL/gG |
| Selectivity class | 3 |
| Lifespan, electrical | min. 1500 operations min. 6000 operations (UL) |
| Overvoltage category | III |
| Pollution degree | 2 |
| Direction of incoming supply | As required |
| Frame | 45 mm |
| Enclosure width | 105 mm |
| Width in number of modular spacings | 2 |
| Built-in depth | 60 mm |
| Mounting width | 17.7 mm |
| Mounting width per pole | 17.7 mm |
| Mounting Method | Top-hat rail IEC/EN 60715 |
| Mounting position | As required |
| Degree of protection | IP40 (when fitted) IP20 (IEC) IP20 UL/CSA Type: - |
| Terminals (top and bottom) | Lift terminal / ring-tongue |
| Connectable conductor cross section (solid-core) - min | 1 mm² |
| Connectable conductor cross section (solid-core) - max | 25 mm² |
| Connectable conductor cross section (multi-wired) - min | 1 mm² |
| Connectable conductor cross section (multi-wired) - max | 25 mm² |
| Terminal capacity of screw terminals for main cable | 10 mm² (2x) |
| Terminal capacity (control cable) | 25 mm² (1x) |
| Terminal protection | Finger and hand touch safe, DGUV VS3, EN 50274 |
| Contact position indicator color | Red / green |
| Tightening torque | Max. 2.4 Nm UL: 4 Nm (36 lb-in) for AWG 6 UL: 2.4 Nm (21 lb-in) for AWG 18 - AWG 12 UL: 2.8 Nm (25 lb-in) for AWG 10 - AWG 8 |
| Lifespan, mechanical | 10000 operations |
| Rated operational current for specified heat dissipation (In) | 50 A |
| Heat dissipation per pole, current-dependent | 0 W |
| Static heat dissipation, non-current-dependent | 0 W |
| Heat dissipation capacity | 0 W |
| Ambient operating temperature - min | -25 °C |
| Ambient operating temperature - max | 75 °C |
| Ambient operating temperature (UL) - min | -5 °C |
| Ambient operating temperature (UL) - max | 40 °C |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| Accessories required | Z-IHK-NA 113895 |
| Current limiting class | 3 |
| Features | Additional equipment possible |
| Fitted with: | Z-IS/SPE-1TE 274418 |
| Functions | Current limiting circuit breaker |
| Internal resistance at room temperature (single-pole, 50 Hz) | 1.6 mΩ |
| Special features |
|
| Suitable for | Flush-mounted installation |
| Used with | FAZ-XAA-NA110-415V AC 102036 (Shunt trip release)FAZ-XAA-NA12-110V AC 102037 (Shunt trip release) FAZ-RT Miniature circuit breaker FAZ-XAA-NA110-415V AC 102036 (Shunt trip release) FAZ-XAA-NA12-110V AC 102037 (Shunt trip release) |
| Feature Name | Feature Value |
|---|---|
| Built-in depth (EF000218) | 60 mm |
| Release characteristic (EF000889) | B |
| Number of poles (total) (EF008618) | 2 |
| Number of protected poles (EF005548) | 2 |
| Rated current (EF000227) | 50 A |
| Rated voltage (EF000228) | 240 V |
| Rated insulation voltage Ui (EF001366) | 440 V |
| Rated impulse withstand voltage Uimp (EF011980) | 4 kV |
| Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V (EF009556) | 15 kA |
| Voltage type (EF000187) | AC |
| Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V (EF009555) | 15 kA |
| Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V (EF009557) | 10 kA |
| Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V (EF009558) | 14 kA |
| Frequency (EF000416) | 50 Hz |
| Power loss (EF005387) | 8.8 W |
| Current limiting class (EF002568) | 3 |
| Flush-mounted installation (EF007517) | Yes |
| Concurrently switching neutral conductor (EF005997) | No |
| Over voltage category (EF002569) | 3 |
| Pollution degree (EF002570) | 2 |
| Additional equipment possible (EF008148) | Yes |
| Width in number of modular spacings (EF002950) | 2 |
| Degree of protection (IP) (EF005474) | IP20 |
| Ambient temperature during operating (EF007515) | -25 °C |
| Connectable conductor cross section multi-wired (EF007343) | 1 mm² |
| Connectable conductor cross section solid-core (EF007337) | 1 mm² |
| Explosion-proof (EF004663) | No |