View larger
EU6E-SWD-2D2D-1 183264 Y7-183264 EATON ELECTRIC SWD Block module I/O module IP69K, 24 V DC, 2 inputs with po..
EU6E-SWD-2D2D-1
183264
Y7-183264
EATON - MOELLER
1 Pcs.
Automation > Fieldbus, decentr. periphery - digital I/O module
Smartwire Darwin
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller EU6E-SWD-2D2D-1 is an SWD Block module I/O module utilized in automated control setups to link field devices with communication networks. Such modules handle discrete signal collection and distribution, allowing programmable logic controllers to monitor sensors and drive actuators across complex machinery.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage AC 50 Hz (EF007532): 0 V
- Supply voltage AC 60 Hz (EF007533): 0 V
- Supply voltage DC (EF007534): 20.4 V
- Voltage type (supply voltage) (EF002991): DC
- Number of digital inputs (EF001992): 2
- Number of digital outputs (EF001993): 2
- Digital inputs configurable (EF008516): No
- Digital outputs configurable (EF008520): No
- Input current at signal 1 (EF001428): 4 mA
- Permitted voltage at input (EF007554): 20.4 V
- Type of voltage (input voltage) (EF003033): DC
- Output current (EF003202): 0.5 A
- Permitted voltage at output (EF007553): 20.4 V
- Type of output voltage (EF008222): DC
- Short-circuit protection, outputs available (EF003203): Yes
- Number of HW-interfaces industrial Ethernet (EF003020): 0
More info
▲General specifications
UL
IEC/EN 61131-2
Features & Functions
Overload proof (with diagnostics)
Overload protection (sensor supply)
Fieldbus connection over separate bus coupler possible
For connection of digital I/O signals
General
70 mA, Max. current consumption per M12 I/O plug, Sensor supply, SmartWire-DT network
Wall mounting/direct mounting
Ambient conditions, mechanical
Climatic environmental conditions
Dry heat to IEC 60068-2-2
Electro magnetic compatibility
1 kV, SmartWire-DT cable, according to IEC/EN 61131-2, Level 3
1 kV, Signal cable, according to IEC/EN 61131-2, Level 3
1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008)
10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008)
1 kV, Surge I/O cables, Surge (IEC/EN 61131-2:2008, Level 1), EMC
Electrical rating
Communication
5-pin M12 socket (A-keyed), Supply and I/O sensor
SWD-OUT: M12 socket (A-keyed), 5 pole
2 MBit/s, SmartWire-DT
Status indication of input: Yellow LED
Input/Output
High: > 15 V DC