View larger
ESR5-NV3-30 118705 Y7-118705 EATON ELECTRIC Safety relay emergency stop/protective door/light curtain, 24 V ..
ESR5-NV3-30
118705
Y7-118705
EATON - MOELLER
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Relay timers (KETR, KEMR, KESR)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller ESR5-NV3-30 is a safety relay engineered to monitor emergency stop buttons, protective doors, and light curtains in automated production lines. Such devices process safety-related signals from sensors and switches, providing reliable switching logic to remove power from hazardous machine actuators upon command. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Model (EF000010): Basic device
- Suitable for rail mounting (EF003972): Yes
- With detachable clamps (EF003340): Yes
- Type of electric connection (EF003961): Screw connection
- Voltage type (supply voltage) (EF002991): AC
- Supply voltage AC 50 Hz (EF007532): 0 V
- Supply voltage AC 60 Hz (EF007533): 0 V
- Supply voltage DC (EF007534): 24 V
- Suitable for monitoring of position switches (EF007270): Yes
- Suitable for monitoring of valves (EF007272): No
- Suitable for monitoring of tactile sensors (EF007271): No
- Suitable for monitoring of magnetic switches (EF007266): No
- Suitable for monitoring of proximity switches (EF007267): No
- Evaluation inputs (EF008245): One- and two-channel
- Power consumption (EF000346): 7.8 W
- With start input (EF003342): Yes
More info
▲General specifications
CE
CSA Class No.: 3211-83; 3211-03
IEC 61508, Parts 1-7
UL File No.: E29184
UL 508
UL report applies to both US and Canada
IEC/EN 60204
EN 50178
Certified by UL for use in Canada
IEC 62061
2014/30/EU
CSA-C22.2 No. 14-95
UL Category Control No.: NKCR; NKCR7
UL
Machines 2006/42/EG
Feature & Functions
Manual start
Basic insulation
2 Non-delayed enable current paths
Start input
Selectable cross-circuit detection
Detachable clamps
Feedback circuit
Approval according to UL
2-channel
Time function
Enclosure: Polyamide (PA), not reinforced
General information
IP20
Installation location: ≥ IP54
Enclosure: IP20
According to EN 662061_x
Rail mounting possible
Cat. 4, Category
18 x 10-10, PFHd, Probability of failure per hour
SIL 3, Safety integrity level
SILCL 3, Safety integrity level claim limit
SIL 3, Safety integrity level, In accordance with IEC 61508
1
Module used to safely interrupt electrical circuits
Safety relay for monitoring emergency stop and protective door switch
Monitoring of optoelectronic protection equipment
Monitoring of emergency-stop circuits
Safety position switch with mechanical securing action LS-S…MT-ZBZ
Ambient conditions, mechanical
5 A at 3600 O/h, AC-15 at 230 V, Outputs
0.4 W
In accordance with IEC 60947-5-1, Outputs
Climatic environmental conditions
Damp heat, constant, to IEC 60068-2-3
Cold to EN 60068-2-1
Condensation: Non-condensing
Terminal capacities
24 - 12 AWG, solid or stranded
1 x (0.2 – 2.5) mm², solid
2 x (0.25 – 1) mm², flexible with ferrule
1 x (0.25 – 2.5) mm², flexible with ferrule
2, Terminal screw, Pozidriv screwdriver
Electrical rating
Approx. 24 V DC at input, starting and feedback circuit
230 V AC
6A gL/gG, NEOZED (N/C), Output fuse, External, Output data
Input/Output
42 W max., inductive load (τ = 40 ms), at 24 V DC
88 W max., resistive load (τ = 0 ms), at 220 V DC
1500 VA, max., resistive load (τ = 0 ms), at 250 V AC
23 W max., inductive load (τ = 40 ms), at 220 V DC
288 W max., resistive load (τ = 0 ms), at 48 V DC
33 W max., inductive load (τ = 40 ms), at 48 V DC
25 W max., inductive load (τ = 40 ms), at 110 V DC
90 W max., resistive load (τ = 0 ms), at 110 V DC
150 ms typ. (controlled start, K1, K2 - for UN manual operation)
150 ms typ. (controlled start, K1, K2 - for UN automatic mode)
150 ms typ. (at Uₑ in manual mode)
20 ms (non-delayed contacts)
6 A N/C, Limiting continuous current