View larger
ESR5-NV3-300 171858 Y7-171858 EATON ELECTRIC Safety relays for emergency stop/protective door/light curtain ..
ESR5-NV3-300
171858
Y7-171858
EATON - MOELLER
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Relay timers (KETR, KEMR, KESR)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ESR5-NV3-300 171858 Y7-171858 EATON ELECTRIC Safety relays for emergency stop/protective door/light curtain .. produced by Eaton Moeller is utilized to monitor safety circuits associated with emergency stop buttons, access doors, and optical light curtains. It ensures reliable interruption of control voltage to protected machine zones whenever an unsafe condition occurs.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Model (EF000010): Basic device
- Suitable for rail mounting (EF003972): Yes
- With detachable clamps (EF003340): Yes
- Type of electric connection (EF003961): Screw connection
- Voltage type (supply voltage) (EF002991): DC
- Supply voltage AC 50 Hz (EF007532): 0 V
- Supply voltage AC 60 Hz (EF007533): 0 V
- Supply voltage DC (EF007534): 24 V
- Suitable for monitoring of position switches (EF007270): Yes
- Suitable for monitoring of valves (EF007272): No
- Suitable for monitoring of tactile sensors (EF007271): No
- Suitable for monitoring of magnetic switches (EF007266): No
- Suitable for monitoring of proximity switches (EF007267): No
- Evaluation inputs (EF008245): One- and two-channel
- Power consumption (EF000346): 5.43 W
- With start input (EF003342): Yes
More info
▲General specifications
CE
CSA-C22.2 No. 14-95
UL File No.: E29184
UL report applies to both US and Canada
EN 50178
EN ISO 13849-1
IEC 62061
UL
UL Category Control No.: NKCR; NKCR7
CSA Class No.: 3211-83; 3211-03
IEC 61508, Parts 1-7
IEC/EN 60204
Certified by UL for use in Canada
UL 508
Machines 2006/42/EG
Feature & Functions
3 Non-delayed enable current paths
Monitored reset
Automatic start
6 kV between the enable current paths (13/14, 23/24, 33/34) and the remaining rungs, as well as between 13/14, 23/24, 33/34 in relation to each other
Manual start
Reinforced insulation
Basic insulation
Start input
Approval according to UL
Detachable clamps
Approval for TÜV
2-channel
General information
Enclosure: IP20
Terminals: IP20
IP20
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
3.6 x 10-10, PFHd, Probability of failure per hour
Off-delay contacts, SILCL 2 as per IEC 62061
SIL 3, Safety integrity level, In accordance with IEC 61508
Cat. 4, Category
Non-time-delay contacts, SILCL 3 as per IEC 62061 and SIL 3 as per IEC 61508
Module used to safely interrupt electrical circuits
Monitoring of position switches
Safety relay for monitoring emergency stop and protective door switch
Ambient conditions, mechanical
19 Months (Low Demand)
2.5 A at 3600 O/h, DC-13 at 24 V, Outputs
0.4 W
In accordance with IEC 60947-5-1, Outputs
4 A at 360 O/h, AC-15 at 230 V, Outputs
Climatic environmental conditions
Dry heat to IEC 60068-2-2
Damp heat, constant, to IEC 60068-2-3
Condensation: Non-condensing
Terminal capacities
2 x (0.2 – 1) mm², solid
2 x (0.25 – 1) mm², flexible with ferrule
1 x (0.25 – 2.5) mm², flexible with ferrule
24 - 12 AWG, solid or stranded
0.6 x 3.5 mm, Terminal screws
Electrical rating
230 V AC
24 V DC (power supply)
Time-delay 10-A gL/gG Neozed fuse, For output circuits, External
10A gL/gG, NEOZED (delayed), Output fuse, External, Output data
Input/Output
1500 VA, max., resistive load (τ = 0 ms), at 250 V AC
144 W max., resistive load (τ = 0 ms), at 24 V DC
288 W max., resistive load (τ = 0 ms), at 48 V DC
40 W max., inductive load (τ = 40 ms), at 48 V DC
35 W max., inductive load (τ = 40 ms), at 110 V DC
42 W max., inductive load (τ = 40 ms), at 24 V DC
88 W max., resistive load (τ = 0 ms), at 220 V DC
77 W max., resistive load (τ = 0 ms), at 110 V DC
70 ms typ. (at Uₑ in manual mode)
600 ms typ. (K1, K2 - for UN automatic mode)
70 ms typ. (K1, K2 - for UN manual operation)
6 A N/O, Limiting continuous current