View larger
ESR5-NO-31-UC 191796 Y7-191796 EATON ELECTRIC Safety relay emergency stop/protective door/light curtain moni..
ESR5-NO-31-UC
191796
Y7-191796
EATON - MOELLER
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Relay timers (KETR, KEMR, KESR)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Eaton Moeller ESR5-NO-31-UC safety relay functions as a core monitoring unit for emergency stop loops, light curtains, and protective interlocking doors. Industrial safety relays ensure that machine hazards are immediately neutralized when safety perimeters are breached during operation.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Model (EF000010): Basic device
- Suitable for rail mounting (EF003972): Yes
- With detachable clamps (EF003340): Yes
- Type of electric connection (EF003961): Screw connection
- Voltage type (supply voltage) (EF002991): AC/DC
- Supply voltage AC 50 Hz (EF007532): 24 V
- Supply voltage AC 60 Hz (EF007533): 24 V
- Supply voltage DC (EF007534): 24 V
- Suitable for monitoring of position switches (EF007270): No
- Suitable for monitoring of valves (EF007272): No
- Suitable for monitoring of tactile sensors (EF007271): No
- Suitable for monitoring of magnetic switches (EF007266): Yes
- Suitable for monitoring of proximity switches (EF007267): No
- Evaluation inputs (EF008245): One- and two-channel
- Power consumption (EF000346): 2.9 W
- With start input (EF003342): Yes
More info
▲General specifications
CSA-C22.2 No. 14-95
IEC/EN 60947-5-1
UL 508
2014/30/EU
CE
IEC 62061
UL report applies to both US and Canada
EN 50156-1
EN ISO 13849-1
UL
UL File No.: E29184
IEC 61508, Parts 1-7
Machines 2006/42/EG
Feature & Functions
4 kV basic insulation between all current paths and enclosure
4 kV basic insulation between 23/24 and 33/34 enable signal current paths and 41/42 signaling current path
Manual start
3 Non-delayed enable current paths
Safe insulation
Automatic start
6 kV reinforced insulation between all other current paths
Approval according to UL
Start input
Feedback circuit
1-channel
General information
Installation location: ≥ IP54
IP20
Enclosure: IP20
Rail mounting possible
SIL 3, Safety integrity level, In accordance with IEC 61508
10 x 10-10, PFHd, Probability of failure per hour
SILCL 3, Safety integrity level claim limit
SIL 3, Safety integrity level
Monitoring of emergency-stop circuits
If the sensor circuit is interrupted, the safety relay switches to safe mode
Module used to safely interrupt electrical circuits
Monitoring of optoelectronic protection equipment
Safety relay for monitoring one or two-channel signal generators and control of actuators
Ambient conditions, mechanical
240 Months (High Demand)
5 A, DC-13 at 24 V, Outputs
Climatic environmental conditions
Electrical rating
Input/Output
35 W max., inductive load (τ = 40 ms), at 110 V DC
1500 VA, max., resistive load (τ = 0 ms), at 250 V AC
48 W max., inductive load (τ = 40 ms), at 24 V DC
33 W max., inductive load (τ = 40 ms), at 220 V DC
< 150 ms typ. (at Uₑ in automatic mode)