View larger
ESR5-BWS-31-24VAC-DC 180413 Y7-180413 EATON ELECTRIC Safety relays for controlled stop/protective door/light..
ESR5-BWS-31-24VAC-DC
180413
Y7-180413
EATON - MOELLER
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Relay timers (KETR, KEMR, KESR)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller ESR5-BWS-31-24VAC-DC safety relays for controlled stop/protective door/light.. are core electrical components designed to monitor hazard-critical circuits in industrial machinery. They continuously supervise emergency stop buttons, interlocks, and light curtains, swiftly interrupting power to dangerous equipment when a safety boundary is breached. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Model (EF000010): Basic device
- Suitable for rail mounting (EF003972): Yes
- With detachable clamps (EF003340): Yes
- Type of electric connection (EF003961): Screw connection
- Voltage type (supply voltage) (EF002991): AC/DC
- Supply voltage AC 50 Hz (EF007532): 24 V
- Supply voltage AC 60 Hz (EF007533): 24 V
- Supply voltage DC (EF007534): 24 V
- Suitable for monitoring of position switches (EF007270): Yes
- Suitable for monitoring of valves (EF007272): No
- Suitable for monitoring of tactile sensors (EF007271): No
- Suitable for monitoring of magnetic switches (EF007266): No
- Suitable for monitoring of proximity switches (EF007267): No
- Evaluation inputs (EF008245): One- and two-channel
- Power consumption (EF000346): 5.16 W
- With start input (EF003342): No
More info
▲General specifications
UL report applies to both US and Canada
UL File No.: E29184
CSA-C22.2 No. 14-95
EN ISO 13849-1
IEC/EN 61000-6-4
CE
IEC 62061
2014/30/EU
IEC/EN 60204
IEC/EN 61000-6-2
UL
Certified by UL for use in Canada
CSA Class No.: 3211-83; 3211-03
UL 508
Machines 2006/42/EG
Feature & Functions
Safe insulation
6 kV between input circuit and enable current paths
Basic insulation
Automatic/manually controlled start
Feedback current path
3 Non-delayed enable current paths
Reinforced insulation
Detachable clamps
Approval for TÜV
Approval according to UL
1-channel
General information
70 mA, DC
Installation location: ≥ IP54
Enclosure: IP20
IP20
Rail mounting possible
SILCL 3, Safety integrity level claim limit
SIL 3, Safety integrity level
EN 574 Type III C
SIL 3, Safety integrity level, In accordance with IEC 61508
5.56 x 10-10, PFHd, Probability of failure per hour
Monitoring of position switches
Safety relay for monitoring emergency stop and protective door switch and light curtains
Monitoring of emergency-stop circuits
Ambient conditions, mechanical
240 Months (High Demand)
3 A at 3600 O/h, DC-13 at 24 V, Outputs
6 A at 360 O/h, DC-13 at 24 V, Outputs
In accordance with IEC 60947-5-1, Outputs
3 A at 3600 O/h, AC-15 at 230 V, Outputs
Climatic environmental conditions
Clearance in air and creepage distances according to EN 50178
Terminal capacities
2 x (0.2 – 1) mm², solid
1 x (0.2 – 2.5) mm², solid
24 - 12 AWG, solid or stranded
1 x (0.25 – 2.5) mm², flexible with ferrule
0.6 x 3.5 mm, Terminal screws
Electrical rating
24 V AC/DC (power supply)
Input/Output
33 W max., inductive load (τ = 40 ms), at 220 V DC
144 W max., resistive load (τ = 0 ms), at 24 V DC
77 W max., resistive load (τ = 0 ms), at 110 V DC
1500 VA, max., resistive load (τ = 0 ms), at 250 V AC
48 W max., inductive load (τ = 40 ms), at 24 V DC
40 W max., inductive load (τ = 40 ms), at 48 V DC
35 W max., inductive load (τ = 40 ms), at 110 V DC
88 W max., resistive load (τ = 0 ms), at 220 V DC
100 ms typ. (K1, K2 - for UN automatic mode)
100 ms typ. (at Uₑ in automatic mode)
25 ms typ. (at Uₑ in manual mode)
6 A N/O, Limiting continuous current