EATON - MOELLER EMS2-ROSF-Z-9-24VDC EMS2-ROSF-Z-9-24VDC 192400 Y7-192400 EATON ELECTRIC Starter electronic Starter inverter 9 A 24 V DC Emergenc.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

EMS2-ROSF-Z-9-24VDC 192400 Y7-192400 EATON ELECTRIC Starter electronic Starter inverter 9 A 24 V DC Emergenc..

EMS2-ROSF-Z-9-24VDC

192400

Y7-192400

EATON - MOELLER

1 Pcs.

Starter electronic; Starter inverter; 9 A; 24 V DC; Emergency Stop; Fuses integrated; Connection-screw EMS2-ROSF-Z-9-24VDC Eaton Moeller® series EMS2 Reversing starter, 24 V DC, 1,5 - 7 (AC-53a), 9 (AC-51) A, Screw terminals, Controlled stop, PTB 19 ATEX 3000 EMS2-ROSF-Z-9-24VDC Reversing starter, Product range: Electronic motor starter, Description: DOL starting, Reversing start, Motor protection, Circuit design: safety output stage with bypass, three-phase disconnect., Controlled stop via additional enable signal terminal up to SIL3/Ple., Conformity, Approval Explosion protection (according to ATEX 94/9/EC): II (2) G [Ex e] [Ex d] [Ex px], II (2) D [Ex t] [Ex p], Conformity, Approval EC-prototype test certification: PTB 13 ATEX 3003, Max. motor rating for three-phase motors, 50 - 60 Hz AC-53a 380 V 400 V 415 V: P= 0.55 - 3 kW, Setting range of overload releases: Ir= 1,5 - 9 A_x, Actuating voltage: 24 V DC , Connection technique: Screw terminals, Stop Function: Controlled stop, Connection to SmartWire-DT: no, Mounting position: Vertical, Motor feeder at bottom, Standards: IEC/EN 60947-4-2, IEC 61508, ISO 13849, UL508

Automation > Motor starter/Motor starter combination
Standard Soft Starters

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

General specifications

Product Name
Eaton Moeller® series EMS2 Reversing starter
Catalog Number
192400
Model Code
EMS2-ROSF-Z-9-24VDC
EAN
4015081930975
Product Length/Depth
114.5 mm
Product Height
160 mm
Product Width
22.5 mm
Product Weight
0.35 kg
Certifications
IEC 61508
IEC/EN 60947-4-2
EN ISO 13849
UL508
UL File No.: E29096
UL Category Control No.: NLDX, NLDX7
PTB 19 ATEX 3000
UL 60947-4-1
CSA-C22.2 No. 60947-4-1-14
CE marking
UL listed
Certified by UL for use in Canada
UL report applies to both US and Canada

Features & Functions

Fitted with:
fuse
Functions
Motor protection
Controlled stop
DOL starting
Reversing start
Temperature compensated overload protection

General

Class
CLASS 10 A
Connection to SmartWire-DT
No
Degree of protection
IP20
NEMA Other
Model
Reversing starter
Mounting method
Mounting on Busbar 30 mm
Rail mounting possible
Motor starter Feeder System
Mounting on Busbar 60 mm
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Mounting position
Motor feeder at bottom
Vertical
Overload release current setting - min
1.5 A
Overload release current setting - max
9 A
Product category
Electronic motor starter
Residual ripple
≤ 5 % (input voltage)
Terminal capacity
0.14 - 2.5 mm², Control circuit cables
0.2 - 2.5 mm², Main cables
Terminal capacity (AWG)
26 - 14, Control circuit cables
24 - 14, Main cables
Type
Reversing starter (complete device)
Voltage type
DC

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
70 °C
Ambient storage temperature - min
40 °C
Ambient storage temperature - max
80 °C

Electro magnetic compatibility

Radio interference class
EN 55011
Class A (EN 61000-6-3, emitted interference, radiated)

Electrical rating

Rated actuating current (Ic)
5 mA
Rated conditional short-circuit current (Iq), type 2, 380 V, 400 V, 415 V
0 A
Rated control supply current Is
40 mA
Rated control supply voltage
19.2 - 30 V DC
Rated control voltage (Uc)
24 V (Actuating circuit ON, L, R)
Rated control supply voltage (Us) at AC, 50 Hz - min
0 V
Rated control supply voltage (Us) at AC, 50 Hz - max
0 V
Rated control supply voltage (Us) at AC, 60 Hz - min
0 V
Rated control supply voltage (Us) at AC, 60 Hz - max
0 V
Rated control supply voltage (Us) at DC - min
24 V
Rated control supply voltage (Us) at DC - max
24 V
Rated operational current (Ie)
9 A
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V
2 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
7 A
Rated operational current (Ie) at AC-51
9 A
Rated operational current (Ie) at AC-53A - max
7 A
Rated operational current (Ie) at DC-13, 24 V
2 A
Rated operational power at AC-3, 220/230 V, 50 Hz
1.5 kW
Rated operational power at AC-3, 380/400 V, 50 Hz
3 kW
Rated operational power at AC-53A, 380/400 V, 50 Hz
3 kW
Rated operational voltage
42 - 550 V
500 V AC
Switching level
-3 - 9.6 V DC, Switching level "Low", Actuating circuit (ON, L, R)
< 5 V DC, Switching level "confirm Off", Actuating circuit (ON, L, R)
19.2 - 30 V DC, Switching level "High", Actuating circuit (ON, L, R)

Contacts

Number of auxiliary contacts (normally closed contacts)
1
Number of auxiliary contacts (normally open contacts)
1
Number of contacts (change-over contacts)
1

Safety

Explosion safety category for dust
ATEX dust-ex-protection, II (2) G [Ex e] [Ex d] [Ex px]
ATEX dust-ex-protection, II (2) D [Ex t] [Ex p]
Safety parameter (EN ISO 13849-1)
3 (safe switch off), Category
PL e, Performance level (safe switch off)
60 (safe switch off) / 70 (motor protection) years; MTTFD
Safety parameter (IEC 62061)
99 % (safe switch off) / 98 % (motor protection), DC
PFHd [FIT]: 2.3 (Safe switch off)
Λsu [FIT]: 1072 (Safe switch off) / 969 (Motor protection)
Λdd [FIT]: 580 (Safe switch off) / 601 (Motor protection)
Λdu [FIT]: 2.3 (Safe switch off) / 11 (Motor protection)
99 %, SFF
SIL 3 (Safe switch off) / SIL 2 (Motor protection)
Opening delay [ms]: 200 (safe switch off) / Class 10A (motor protection)
Λsd [FIT]: 0

Design verification

Equipment heat dissipation, current-dependent Pvid
13 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
9 A
Static heat dissipation, non-current-dependent Pvs
2 W
Heat dissipation details
If necessary, Allow for derating
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 192400 Low-voltage industrial controls and switchgear (EC001037)
Feature Name Feature Value
Type of motor starter (EF009598) Reversing starter
With short-circuit release (EF006691) No
Rated control supply voltage AC 50 Hz (EF003978) 0 V
Rated control supply voltage AC 60 Hz (EF003979) 0 V
Rated control supply voltage DC (EF003980) 24 V
Voltage type for actuating (EF008242) DC
Rated operation power at AC-3, 230 V, 3-phase (EF009599) 1.5 kW
Rated operation power at AC-3, 400 V (EF001364) 3 kW
Rated power, 460 V, 60 Hz, 3-phase (EF009600) 0 kW
Rated power, 575 V, 60 Hz, 3-phase (EF009601) 0 kW
Rated operation current Ie (EF001443) 9 A
Rated operation current at AC-3, 400 V (EF009602) 7 A
Overload release current setting (EF002336) 1.5 A
Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) 0 A
Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) 0 A
Rated conditional short-circuit current, type 2, 230 V (EF009606) 0 A
Rated conditional short-circuit current, type 2, 400 V (EF009605) 0 A
Power consumption (EF000346) 13 W
Number of auxiliary contacts as normally open contact (EF001376) 1
Number of auxiliary contacts as normally closed contact (EF001377) 1
Ambient temperature, upper operating limit (EF009603) 70 °C
Temperature compensated overload protection (EF009604) Yes
Release class (EF006668) CLASS 10 A
Type of electrical connection of main circuit (EF006819) Screw connection
Type of electrical connection for auxiliary- and control current circuit (EF006979) Screw connection
Suitable for rail mounting (EF003972) Yes
With transformer (EF000278) No
Number of command positions (EF001372) 0
Suitable for emergency stop (EF001433) No
Coordination class according to IEC 60947-4-3 (EF012390) Class 2
Number of indicator lights (EF001965) 0
External reset possible (EF003426) No
With fuse (EF006693) Yes
Degree of protection (IP) (EF005474) IP20
Degree of protection (NEMA) (EF011959) Other
Supporting protocol for TCP/IP (EF003050) No
Supporting protocol for PROFIBUS (EF003052) No
Supporting protocol for CAN (EF003053) No
Supporting protocol for INTERBUS (EF003054) No
Supporting protocol for ASI (EF003051) No
Supporting protocol for Modbus (EF003057) No
Supporting protocol for Data-Highway (EF003058) No
Supporting protocol for DeviceNet (EF003059) No
Supporting protocol for SUCONET (EF003060) No
Supporting protocol for LON (EF003017) No
Supporting protocol for PROFINET IO (EF007525) No
Supporting protocol for PROFINET CBA (EF007524) No
Supporting protocol for SERCOS (EF006657) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Supporting protocol for EtherNet/IP (EF007521) No
Supporting protocol for AS-Interface Safety at Work (EF007519) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for INTERBUS-Safety (EF006662) No
Supporting protocol for PROFIsafe (EF007526) No
Supporting protocol for SafetyBUS p (EF007527) No
Supporting protocol for other bus systems (EF003062) No
Width (EF000008) 22.5 mm
Height (EF000040) 160 mm
Depth (EF000049) 114.5 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.