View larger
EMS2-ROSF-Z-3-24VDC 192399 Y7-192399 EATON ELECTRIC Starter electronic Starter inverter 3 A 24 V DC Emergenc..
EMS2-ROSF-Z-3-24VDC
192399
Y7-192399
EATON - MOELLER
1 Pcs.
Automation > Motor starter/Motor starter combination
Standard Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Electronic reversing starters manage the directional rotation and frequent switching cycles of three-phase electric motors using solid-state technology. Eaton Moeller part number EMS2-ROSF-Z-3-24VDC delivers reliable performance with low power dissipation for modern automation setups.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of motor starter (EF009598): Reversing starter
- With short-circuit release (EF006691): No
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Rated operation power at AC-3, 230 V, 3-phase (EF009599): 0.55 kW
- Rated operation power at AC-3, 400 V (EF001364): 1.1 kW
- Rated power, 460 V, 60 Hz, 3-phase (EF009600): 0 kW
- Rated power, 575 V, 60 Hz, 3-phase (EF009601): 0 kW
- Rated operation current Ie (EF001443): 3 A
- Rated operation current at AC-3, 400 V (EF009602): 3 A
- Overload release current setting (EF002336): 0.18 A
- Power consumption (EF000346): 3.5 W
- Ambient temperature, upper operating limit (EF009603): 70 °C
- Temperature compensated overload protection (EF009604): Yes
More info
▲General specifications
UL508
IEC/EN 60947-4-2
EN ISO 13849
UL File No.: E29096
UL Category Control No.: NLDX, NLDX7
PTB 19 ATEX 3000
UL 60947-4-1
CSA-C22.2 No. 60947-4-1-14
CE marking
UL listed
Certified by UL for use in Canada
UL report applies to both US and Canada
Features & Functions
DOL starting
Motor protection
Controlled stop
Reversing start
General
NEMA Other
Rail mounting possible
Motor starter Feeder System
Mounting on Busbar 30 mm
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Motor feeder at bottom
0.14 - 2.5 mm², Control circuit cables
24 - 14, Main cables
Climatic environmental conditions
Electro magnetic compatibility
EN 55011
Electrical rating
500 V AC
< 5 V DC, Switching level "confirm Off", Actuating circuit (ON, L, R)
-3 - 9.6 V DC, Switching level "Low", Actuating circuit (ON, L, R)
Contacts
Safety
ATEX dust-ex-protection, II (2) D [Ex t] [Ex p]
3 (safe switch off), Category
60 (safe switch off) / 70 (motor protection) years; MTTFD
Λsu [FIT]: 1072 (Safe switch off) / 969 (Motor protection)
99 % (safe switch off) / 98 % (motor protection), DC
Opening delay [ms]: 200 (safe switch off) / Class 10 (motor protection)
SIL 3 (Safe switch off) / SIL 2 (Motor protection)
PFHd [FIT]: 2.3 (Safe switch off)
Λdd [FIT]: 580 (Safe switch off) / 601 (Motor protection)
99 %, SFF
Λdu [FIT]: 2.3 (Safe switch off) / 11 (Motor protection)