View larger
EMS2-ROS-T-9-SWD 192390 Y7-192390 EATON ELECTRIC Starter electronic Starter inverter 9-To With SmartWire-DT ..
EMS2-ROS-T-9-SWD
192390
Y7-192390
EATON - MOELLER
1 Pcs.
Automation > Motor starter/Motor starter combination
Standard Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Eaton Moeller electronic reversing starter (EMS2-ROS-T-9-SWD) integrates solid-state switching technology and SmartWire-DT connectivity for advanced motor management. Electronic motor starters offer high switching frequencies and reliable protection for automated production equipment.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of motor starter (EF009598): Reversing starter
- With short-circuit release (EF006691): No
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Rated operation power at AC-3, 230 V, 3-phase (EF009599): 1.5 kW
- Rated operation power at AC-3, 400 V (EF001364): 3 kW
- Rated power, 460 V, 60 Hz, 3-phase (EF009600): 0 kW
- Rated power, 575 V, 60 Hz, 3-phase (EF009601): 0 kW
- Rated operation current Ie (EF001443): 9 A
- Rated operation current at AC-3, 400 V (EF009602): 7 A
- Overload release current setting (EF002336): 1.5 A
- Power consumption (EF000346): 12 W
- Ambient temperature, upper operating limit (EF009603): 55 °C
- Temperature compensated overload protection (EF009604): Yes
More info
▲Delivery program
Reversing start
Motor protection
Circuit design: safety output stage with bypass, three-phase disconnect.
Controlled stop via additional enable signal terminal up to SIL3/Ple.
Operating direction feedback
Enable signal
Motor current in %
Motor current in A
Thermal motor image in %
Overload prewarning
Trip indications (overload, phase failure, etc.)
Set short-circuit release value
Device Type
Manual reset
Automatic reset
II (2) D [Ex tb] [Ex pb]
Technical data
IEC 61508
ISO 13849
UL508
Motor feeder at bottom
EN 61000-6-3, Class A (emitted interference, radiated)
motor protection
λsd [FIT]: 0
λsu [FIT]: 3481 (Sicheres Abschalten) / 2538 (Motorschutz)
λdd [FIT]: 1887 (Sicheres Abschalten) / 1375 (Motorschutz)
λdu [FIT]: 0,3 (Sicheres Abschalten) / 23 (Motorschutz)
SFF [%]: 99
DC [%]: 99 (Sicheres Abschalten) / 98 (Motorschutz)
PFHd[FIT]: 0,3 (Sicheres Abschalten)
SIL 3 (Sicheres Abschalten) / SIL 2 (Motorschutz)