View larger
EMS2-DOS-T-9-SWD
192389
Y7-192389
EATON - MOELLER
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Product Name | Eaton Moeller® series EMS2 DOL starter |
| Catalog Number | 192389 |
| Model Code | EMS2-DOS-T-9-SWD |
| EAN | 4015081930869 |
| Product Length/Depth | 114.5 mm |
| Product Height | 99 mm |
| Product Width | 22.5 mm |
| Product Weight | 0.297 kg |
| Certifications | UL508 IEC 61508 EN ISO 13849 IEC/EN 60947-4-2 UL File No.: E338590 UL Category Control No.: NLDX, NLDX7 PTB 19 ATEX 3000 UL 60947-4-1 CSA-C22.2 No. 60947-4-1-14 CE marking UL listed Certified by UL for use in Canada UL report applies to both US and Canada |
| Functions | Controlled stop Temperature compensated overload protection For connecting to SmartWire-DT for expanded diagnostics DOL starting Motor protection Automatic reset Display of Device Type Display of Enable signal Manual reset Display of Motor current in % Display of Operating direction feedback Operating the motor starter Display of Operational readiness Display of Overload prewarning Display of Set short-circuit release value Display of Thermal motor image in % Display of Trip indications (overload, phase failure, etc.) |
| Class | CLASS 10 |
| Connection to SmartWire-DT | Yes |
| Degree of protection | IP20 NEMA Other |
| Model | Direct starter |
| Mounting method | Top-hat rail fixing (according to IEC/EN 60715, 35 mm) Rail mounting possible |
| Mounting position | Motor feeder at bottom Vertical |
| Overload release current setting - min | 1.5 A |
| Overload release current setting - max | 9 A |
| Product category | Electronic motor starter |
| Protocol | Other bus systems |
| Residual ripple | ≤ 5 % (input voltage) |
| Terminal capacity | 0.2 - 2.5 mm², Main cables, Push-in terminals |
| Terminal capacity (AWG) | 24 - 14, Push-in terminals |
| Type | DOL starter (complete device) |
| Voltage type | DC |
| Ambient operating temperature - min | -5 °C |
| Ambient operating temperature - max | 55 °C |
| Ambient storage temperature - min | 40 °C |
| Ambient storage temperature - max | 80 °C |
| Radio interference class | EN 55011 Class A (EN 61000-6-3, emitted interference, radiated) |
| Inrush current | 120 mA (draw) |
| Rated actuating current (Ic) | 5 mA |
| Rated control supply current Is | 60 mA |
| Rated control supply voltage | 19.2 - 30 V DC |
| Rated control voltage (Uc) | 24 V (Actuating circuit ON, L, R) |
| Rated control supply voltage (Us) at DC - min | 24 V |
| Rated control supply voltage (Us) at DC - max | 24 V |
| Rated operational current (Ie) | 9 A |
| Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V | 7 A |
| Rated operational current (Ie) at AC-51 | 9 A |
| Rated operational current (Ie) at AC-53A - max | 7 A |
| Rated operational power at AC-3, 220/230 V, 50 Hz | 1.5 kW |
| Rated operational power at AC-3, 380/400 V, 50 Hz | 3 kW |
| Rated operational power at AC-53A, 380/400 V, 50 Hz | 3 kW |
| Rated operational voltage | 42 - 550 V 500 V AC |
| Switching level | 19.2 - 30 V DC, Switching level "High", Actuating circuit (ON, L, R) < 5 V DC, Switching level "confirm Off", Actuating circuit (ON, L, R) -3 - 9.6 V DC, Switching level "Low", Actuating circuit (ON, L, R) |
| Number of auxiliary contacts (normally closed contacts) | 0 |
| Number of auxiliary contacts (normally open contacts) | 0 |
| Explosion safety category for dust | ATEX dust-ex-protection, II (2) G [Ex e] [Ex d] [Ex px] ATEX dust-ex-protection, II (2) D [Ex t] [Ex p] |
| Safety parameter (EN ISO 13849-1) | 3, Category PL e, Performance level 60 (safe switch off) / 82 (motor protection) years; MTTFD |
| Safety parameter (IEC 62061) | Opening delay [ms]: 200 (safe switch off) / Class 10A (motor protection) 99 % (safe switch off) / 98 % (motor protection), DC |
| Equipment heat dissipation, current-dependent Pvid | 12 W |
| Heat dissipation capacity Pdiss | 0 W |
| Heat dissipation per pole, current-dependent Pvid | 0 W |
| Rated operational current for specified heat dissipation (In) | 9 A |
| Static heat dissipation, non-current-dependent Pvs | 2 W |
| Heat dissipation details | If necessary, Allow for derating |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| Feature Name | Feature Value |
|---|---|
| Type of motor starter (EF009598) | Direct starter |
| With short-circuit release (EF006691) | No |
| Rated control supply voltage AC 50 Hz (EF003978) | 0 V |
| Rated control supply voltage AC 60 Hz (EF003979) | 0 V |
| Rated control supply voltage DC (EF003980) | 24 V |
| Voltage type for actuating (EF008242) | DC |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | 1.5 kW |
| Rated operation power at AC-3, 400 V (EF001364) | 3 kW |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | 0 kW |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | 0 kW |
| Rated operation current Ie (EF001443) | 9 A |
| Rated operation current at AC-3, 400 V (EF009602) | 7 A |
| Overload release current setting (EF002336) | 1.5 A |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | 0 A |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | 0 A |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | 0 A |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | 0 A |
| Power consumption (EF000346) | 12 W |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Ambient temperature, upper operating limit (EF009603) | 55 °C |
| Temperature compensated overload protection (EF009604) | Yes |
| Release class (EF006668) | CLASS 10 |
| Type of electrical connection of main circuit (EF006819) | Spring clamp connection |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | Spring clamp connection |
| Suitable for rail mounting (EF003972) | Yes |
| With transformer (EF000278) | No |
| Number of command positions (EF001372) | 0 |
| Suitable for emergency stop (EF001433) | No |
| Coordination class according to IEC 60947-4-3 (EF012390) | Class 1 |
| Number of indicator lights (EF001965) | 0 |
| External reset possible (EF003426) | No |
| With fuse (EF006693) | No |
| Degree of protection (IP) (EF005474) | IP20 |
| Degree of protection (NEMA) (EF011959) | Other |
| Supporting protocol for TCP/IP (EF003050) | No |
| Supporting protocol for PROFIBUS (EF003052) | No |
| Supporting protocol for CAN (EF003053) | No |
| Supporting protocol for INTERBUS (EF003054) | No |
| Supporting protocol for ASI (EF003051) | No |
| Supporting protocol for Modbus (EF003057) | No |
| Supporting protocol for Data-Highway (EF003058) | No |
| Supporting protocol for DeviceNet (EF003059) | No |
| Supporting protocol for SUCONET (EF003060) | No |
| Supporting protocol for LON (EF003017) | No |
| Supporting protocol for PROFINET IO (EF007525) | No |
| Supporting protocol for PROFINET CBA (EF007524) | No |
| Supporting protocol for SERCOS (EF006657) | No |
| Supporting protocol for Foundation Fieldbus (EF007522) | No |
| Supporting protocol for EtherNet/IP (EF007521) | No |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | No |
| Supporting protocol for DeviceNet Safety (EF007520) | No |
| Supporting protocol for INTERBUS-Safety (EF006662) | No |
| Supporting protocol for PROFIsafe (EF007526) | No |
| Supporting protocol for SafetyBUS p (EF007527) | No |
| Supporting protocol for other bus systems (EF003062) | Yes |
| Width (EF000008) | 22.5 mm |
| Height (EF000040) | 99 mm |
| Depth (EF000049) | 114.5 mm |