EMS-DOS-T-9-SWD 170111 EATON ELECTRIC Starter Direct 9 SWD With emergency stop
EMS-DOS-T-9-SWD
170111
EATON - MOELLER
1 Pcs.
Automation > Motor starter/Motor starter combination
Standard Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Network-integrated motor starters such as the Eaton Moeller EMS-DOS-T-9-SWD enable precise electrical switching and communication within modern control architectures. These direct starters streamline wiring processes and deliver dependable overload protection for connected automation assets.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of motor starter (EF009598): Direct starter
- With short-circuit release (EF006691): No
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Rated operation power at AC-3, 230 V, 3-phase (EF009599): 1.5 kW
- Rated operation power at AC-3, 400 V (EF001364): 3 kW
- Rated power, 460 V, 60 Hz, 3-phase (EF009600): 2.2 kW
- Rated power, 575 V, 60 Hz, 3-phase (EF009601): 0 kW
- Rated operation current Ie (EF001443): 9 A
- Rated operation current at AC-3, 400 V (EF009602): 7 A Overload release current setting (EF002336): 1.5 A
- Ambient temperature, upper operating limit (EF009603): 40 °C
- Temperature compensated overload protection (EF009604): Yes
- Release class (EF006668): CLASS 10
More info
▲Delivery program
Motor protection
Circuit design: safety output stage with bypass, three-phase disconnect.
Controlled stop via additional enable signal terminal up to SIL3/Ple.
Operating direction feedback
Enable signal
Motor current in %
Motor current in A
Thermal motor image in %
Overload prewarning
Trip indications (overload, phase failure, etc.)
Set short-circuit release value
Device Type
Manual reset
Automatic reset
Technical data
1 x AWG20 - 14 mm2
1 x AWG24 - 14 mm2
2 x AWG24 - 16 mm2
10A (Ir > 4 A) CLASS
20 (automatic restart) min.
If ≧ 67, pick-up time of 1.8 s %
If ≧ 67, pick-up time of 1.8 s %
50 kA, 500 V AC: fuse 30 A CCMR
50 kA, 415 V AC: PKM0-4
15 kA, 415 V AC: PKM0-6,3
2.5 kA, 400 V AC: FAZ-B16/3
1.4 - 2 GHz: 10
2.0 - 2.7 GHz: 3 V/m
EN 61000-6-3, Class A (emitted interference, radiated)
IEC/EN 61000-4-4, level 3 kV
2 kV (asymmetrical)
according to IEC/EN 61000-4-5
motor protection
λsu [FIT]: 1321 (Sicheres Abschalten) / 1061 (Motorschutz)
λdd [FIT]: 685 (Sicheres Abschalten) / 577 (Motorschutz)
λdu [FIT]: 0,1 (Sicheres Abschalten) / 18 (Motorschutz)
SFF [%]: 99 (Sicheres Abschalten) / 98 (Motorschutz)
DC [%]: 99 (Sicheres Abschalten) / 96 (Motorschutz)
motor protection