View larger
EMS-DO-T-2,4-SWD 170106 EMS-DO-T-2P4-SWD EATON ELECTRIC DOL starters 2, 4 A, SWD
EMS-DO-T-2,4-SWD
170106
EMS-DO-T-2P4-SWD
EATON - MOELLER
1 Pcs.
Automation > Motor starter/Motor starter combination
Standard Soft Starters
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
EMS-DO-T-2,4-SWD 170106 EMS-DO-T-2P4-SWD EATON ELECTRIC DOL starters 2, 4 A, SWD is a direct-on-line motor starter equipped with SmartWire-DT connectivity for streamlined communication in automated architectures. This starter manages motor activation while integrating network diagnostics to optimize panel wiring and maintenance routines. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of motor starter (EF009598): Direct starter
- With short-circuit release (EF006691): No
- Rated control supply voltage AC 50 Hz (EF003978): 0 V
- Rated control supply voltage AC 60 Hz (EF003979): 0 V
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Rated operation power at AC-3, 230 V, 3-phase (EF009599): 0.37 kW
- Rated operation power at AC-3, 400 V (EF001364): 0.75 kW
- Rated power, 460 V, 60 Hz, 3-phase (EF009600): 0.736 kW
- Rated power, 575 V, 60 Hz, 3-phase (EF009601): 0 kW
- Rated operation current Ie (EF001443): 2.4 A
- Rated operation current at AC-3, 400 V (EF009602): 2.4 A
- Overload release current setting (EF002336): 0.18 A
- Ambient temperature, upper operating limit (EF009603): 60 °C
- Temperature compensated overload protection (EF009604): Yes
- Release class (EF006668): CLASS 10
More info
▲Delivery program
Motor protection
Circuit design: safety output stage with bypass, three-phase disconnect.
Motor current additionally adjustable via SmartWire-DT.
Operating direction feedback
Motor current in %
Motor current in A
Thermal motor image in %
Overload prewarning
Trip indications (overload, phase failure, etc.)
Set short-circuit release value
Device Type
Manual reset
Automatic reset
Technical data
1 x AWG20 - 14 mm2
1 x AWG24 - 14 mm2
2 x AWG24 - 16 mm2
20 (automatic restart) min.
If ≧ 67, pick-up time of 1.8 s %
If ≧ 67, pick-up time of 1.8 s %
50 kA, 500 V AC: fuse 30 A CCMR
50 kA, 415 V AC: PKM0-4
15 kA, 415 V AC: PKM0-6,3
2.5 kA, 400 V AC: FAZ-B16/3
1.4 - 2 GHz: 10
2.0 - 2.7 GHz: 3 V/m
EN 61000-6-3, Class A (emitted interference, radiated)
IEC/EN 61000-4-4, level 3 kV
2 kV (asymmetrical)
according to IEC/EN 61000-4-5