View larger
EMR6-W300-C-1 184776 Y7-184776 EATON ELECTRIC Phase monitoring relays, On- and Off-delayed, 160 300 V AC, 50..
EMR6-W300-C-1
184776
Y7-184776
EATON - MOELLER
1 Pcs.
Automation > Phase monitoring relay
Relay timers (KETR, KEMR, KESR)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Eaton Moeller EMR6-W300-C-1 phase monitoring relay is utilized within electrical distribution systems to detect phase loss, incorrect rotation, and voltage imbalances in three-phase networks. Industrial installations depend on phase monitors to prevent catastrophic motor failures caused by unstable power inputs.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Type of electric connection (EF003961): Screw connection
- With detachable clamps (EF003340): No
- External power supply required (EF003292): No
- Voltage type (supply voltage) (EF002991): AC
- Supply voltage AC 50 Hz (EF007532): 160 V
- Supply voltage AC 60 Hz (EF007533): 160 V
- Phase sequence monitoring (EF003412): Yes
- Phase failure detection (EF003413): Yes
- Function under voltage detection (EF003414): Yes
- Function over voltage detection (EF003415): Yes
- Phase imbalance monitoring (EF003416): No
- Voltage measuring range (EF002486): 160 V
- Min. adjustable delay-on energization time (EF008190): 0.1 s
- Max. permitted delay-on energization time (EF008189): 30 s
- Min. adjustable off-delay time (EF008192): 0.1 s
- Max. permitted off-delay time (EF008191): 30 s
More info
▲General specifications
UL
GL
CCC
IEC
Features & Functions
Under voltage detection
Phase failure detection
On- and Off-delayed
Phase sequence monitoring
Overvoltage
Phase sequence (can be deactivated)
Undervoltage
General
Enclosure: IP50
Status indication of Overvoltage: Red LED (F1 on)
Status indication of Phase failure: F1 red, solid light and F2 red, flashing light
Status indication of Phase sequence fault: Red, flashing light (F1 and F2 alternating)
Status indication of Relay energized: Yellow, solid light (R/T)
Status indication of Supply voltage: Yellow LED
Status indication of Delay time running: Yellow, flashing light (R/T)
Status indication of Supply voltage: Yellow, solid light
Status indication of Undervoltage: Red LED (F2 on)
Status indication of Overvoltage: F1 red, solid light
Climatic environmental conditions
Electro magnetic compatibility
Terminal capacities
1 x (0.5-2.5) mm², (1 x (18-14) AWG), solid
Min. 0.6 Nm, Screw terminals
Timing cycle
0.2 s, Response delay time
0.5 %, Time error within supply voltage
0.06 %/°C, Time error within temperature range
Adjustable from 0.1 – 30 s, Reset delay/Off-delay time
Power supply
0.85 x Uc
Measuring circuits
Relay output contacts
4 A at DC-12, 24 V
3 A at AC-15, 230 V
4 A at AC-12, 230 V